Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1006534.1
Update Date:2008-12-29
Keywords:

Solution Type  Problem Resolution Sure

Solution  1006534.1 :   Sun StorEdge[TM] 3510 FC Array: Repeated disk failures  


Related Items
  • Sun Storage 3510 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 3xxx Arrays
  •  

PreviouslyPublishedAs
209134


Symptoms
Sun StorEdge[TM] 3510 FC Array (SE3510FC) suffers from repeated disk failures.


Resolution
If SE3510FC suffers from repeated disk failures, with the same disks failing again and again, or if only the disk LESB counters for certain disks or slots continue to increase without any apparent cause, then the problem source may be the FC Expansion I/O Module (370-5538 or equivalent).

The FC Expansion I/O Module and the RAID controller I/O module not only provide external array connections ( and in the case of the RAID module, house the controller CPU board ), but they also contain the circuitry that forms the "back-end" drive loops of the array. These are the electronic components that handle the fibre channel protocol and communication between controllers and drives, and that put ports offline and online as appropriate.

Since faults in those components may cause fibre channel errors to be recorded on the drive loops, the RAID I/O Module or "JBOD" FC Expansion I/O module should be considered as possible FRUs to be replaced if drive loop error counters increase rapidly, or if the RAID controller inappropriately fails disk drives.

The midplane or chassis of the array contains no active components that make up the drive channels, apart from connectors and wiring. Replacing the array chassis or midplane when fibre channel error counters increase for certain drive slots would therefore be pointless. This should only be done when a connector or printed circuit track itself is confirmed to be faulty.

The FC error counters can be checked using sccli commands:

diag error channel 2 target all

diag error channel 3 target all

Please note that with sccli version 2.1.x , and in the case of a single controller array or dual controllers array with one in failed state then the sccli command is unable to show the values for channel 3.



Relief/Workaround




Product
Sun StorageTek 3510 FC Array

Internal Comments
Read:

Bug 6361326 for sccli 2.1.x issue.


Minnow, StorEdge, SE3510FC, 3350, multiple, disk, failure, single, controller, error
Previously Published As
83485

Change History
Date: 2007-11-27
User Name: 97961
Action: Approved
Comment: Publishing. No further edits required.
Version: 8
Date: 2007-11-27
User Name: 97961
Action: Accept
Comment:
Version: 0
Date: 2007-11-27
User Name: 84756
Action: Approved
Comment: After correcting Natalia's update , and take into account the remark of the final review , I have moved the CR number to internal section.
Document ready for publishing.

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback