Solution Type Problem Resolution Sure Solution 1006438.1 : Sun Fire[TM] V250 may falsely report fan failures
PreviouslyPublishedAs 209027 Symptoms A health check is run every 24 hours on the fans. Sometimes during this test an incorrect fan speed is read leading to a fan being marked as faulty when it is not. A message is displayed on the console, indicating that a fan has faulted: "ENCLOSURE_FAN @ FT1.F0.RS has FAULTED." OR "ENCLOSURE_FAN @ FT2.F0.RS has FAULTED." This message is incorrect as the fan is not faulty, it is just the fan speed reading that was wrong. Resolution This problem has been fixed in Sun Advanced Lights Out Manager (ALOM) 1.5. To check the ALOM version run the following command. /usr/platform/SUNW,Sun-Fire-V250/sbin/scadm version The ALOM 1.5. software and documentation can be downloaded from Sun Download Center Additional Information The problem is documented in Product Sun Fire V250 Server Internal Comments This and other issues on the Sun Fire V250 can be found at: http://panacea.uk.oracle.com/twiki/bin/view/Products/ProdIssuesSunFireV250 This Symptom Resolution was composed with input from Dale Gaudry who encountered this problem and found the relevant bug. ALOM, fan, failure Previously Published As 78834 Change History Date: 2010-05-12 User name: Dencho Kojucharov Action: re-publish (updated Change History) Comments: Currency check, audited by Entry-Level SPARC Content Lead Date: 2004-11-02 User Name: 36642 Action: Approved Comment: The document is properly trademarked. Acronyms were expanded upon. No duplicates. This is ready for SunSolve. Version: 3 Date: 2004-10-29 User Name: 36642 Action: Accept Comment: Version: 0 Date: 2004-10-29 User Name: 28241 Action: Approved Comment: Completed the technical review. Made some minor changes Version: 0 Attachments This solution has no attachment |
||||||||||||
|