Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1006438.1
Update Date:2011-05-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  1006438.1 :   Sun Fire[TM] V250 may falsely report fan failures  


Related Items
  • Sun Fire V250 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
209027


Symptoms
A health check is run every 24 hours on the fans. Sometimes during this test
an incorrect fan speed is read leading to a fan being marked as faulty when it
is not.

A message is displayed on the console, indicating that a fan has faulted:

"ENCLOSURE_FAN @ FT1.F0.RS has FAULTED."
OR
"ENCLOSURE_FAN @ FT2.F0.RS has FAULTED."

This message is incorrect as the fan is not faulty, it is just the fan speed
reading that was wrong.

Resolution
This problem has been fixed in Sun Advanced Lights Out Manager (ALOM) 1.5.

To check the ALOM version run the following command.

/usr/platform/SUNW,Sun-Fire-V250/sbin/scadm version

The ALOM 1.5. software and documentation can be downloaded from Sun Download Center


Additional Information
The problem is documented in

Product
Sun Fire V250 Server

Internal Comments
This and other issues on the Sun Fire V250 can be found at:

http://panacea.uk.oracle.com/twiki/bin/view/Products/ProdIssuesSunFireV250

This Symptom Resolution was composed with input from Dale Gaudry who encountered this problem and found the relevant bug.

ALOM, fan, failure
Previously Published As
78834

Change History
Date: 2010-05-12
User name: Dencho Kojucharov
Action: re-publish (updated Change History)
Comments: Currency check, audited by Entry-Level SPARC Content Lead
Date: 2004-11-02
User Name: 36642
Action: Approved
Comment: The document is properly trademarked. Acronyms were expanded upon. No duplicates. This is ready for SunSolve.
Version: 3
Date: 2004-10-29
User Name: 36642
Action: Accept
Comment:
Version: 0
Date: 2004-10-29
User Name: 28241
Action: Approved
Comment: Completed the technical review. Made some minor changes
Version: 0

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback