Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1005847.1
Update Date:2009-09-15
Keywords:

Solution Type  Problem Resolution Sure

Solution  1005847.1 :   Why can't I see newly mapped LUNs on a Sun StorEdge[TM] 9900-series array  


Related Items
  • Sun Storage 9970 System
  •  
  • Sun Storage 9910 System
  •  
  • Sun Storage 9960 System
  •  
  • Sun Storage 9980 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Datacenter Disk
  •  

PreviouslyPublishedAs
208126


Symptoms
After new LUNs are mapped from a StorEdge 9910 or 9960 from the SVP or Remote Console, the Solaris[TM]host does not recognize the new devices, even after editing sd.conf.



Resolution
When LUNs are mapped on the Hitachi 9910 or 9960, LUN assignments are done by associating a LUN number with a particular LDEV ID.

The LUN number that is assigned by the subsystem is hex. The sd driver in Solaris however identifies LUNs by their decimal address - LUN definitions in hex will be ignored . Therefore, any LUN number above 09 needs to be translated to decimal in order to be correctly identified by the sd driver in /kernel/drv/sd.conf.

For example:

/devices/pci@1,4000/fibre-channel@4/sd@4, a

would translate to the following sd.conf entry:

name="sd" class="scsi" target=4 lun= 10

Please note that a reconfiguration boot is required to make any changes in /kernel/drv/sd.conf effective.



Product
Sun StorageTek 9960 System
Sun StorageTek 9910 System
Sun StorageTek 9980 System
Sun StorageTek 9970 System

Internal Comments
For the internal use of Sun Employee's.


Previously Published As
40307

Change History
Date: 2006-01-25
User Name: 7058
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-25
User Name: 7058
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2004-04-29
User Name: 36260
Action: Approved
Comment: Corrected Product metadata tag and removed ? from title.
Version: 0
Date: 2004-04-29
User Name: 36260
Action: Updated
Comment: Need to fix Product metadata tag.
Version: 0
Product_uuid
2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System
2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910
c2428fbe-8ab7-41d0-8b6e-ab489823c9d4|Sun StorageTek 9980 System
4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback