Solution Type Problem Resolution Sure Solution 1005619.1 : SL8500 - Problems Upgrading SL8500 Code Direct Attached
PreviouslyPublishedAs 207801
Applies to:Sun StorageTek SL8500 Modular Library System - Version: Not Applicable and later [Release: N/A and later]All Platforms Checked for relevance on 18-Mar-2011. SymptomsProblems Upgrading SL8500 Code Direct Attached.Several sites have reported issues upgrading SL8500 Library Controller Code and SLC (StreamLine Library Console) Code while being directly attached to port 2B on the HBC card. Code load begins and then stops; the Ethernet LED stops flashing, the connect status turns yellow and then turns red. CauseThe root cause was drivers on the remote PC.SolutionSteps to FollowIt is recommended if a direct attach code upgrade is needed via a cross-over cable the IP connection speed be changed to 10Mb Half-Duplex to help stabilize the connection. Recommended setup for PC's directly attached to port 2B via crossover cable: Example configuration change with Windows XP Professional. - Start Another solution was reported by temporarily installing an IP switch between port 2B and the remote PC. Attachments This solution has no attachment |
||||||||||||
|