Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1005454.1 : Sun StorEdge[TM] 6920: One vdisk in two pools
PreviouslyPublishedAs 207577 Symptoms I have the vdisk "disk/3/7/2/0/0" in the following two pools: pool: DBPRD_array01 pool: Default [sp0]# ./sscs list pool DBPRD_array01 Storage Pool: DBPRD_array01 Description: Storage Domain: DEFAULT Profile: ONI_RAID5_9D_64KB_1MB Total Capacity: 1,090.46GB Allocated Capacity: 1,090.19GB Unallocated Capacity: 0.27GB VDisks: VDisk: disk/3/7/2/0/0 Status: Ok VDisk: disk/4/7/2/2/0 Status: Ok Volumes: Volume: PRD_VOTING_0003 Volume: PRD_ORA_0003 Volume: PRD_ORA_0004 Storage Arrays: Array: array01 Total Capacity: 1.0649 TB Configured Capacity: 1.0646 TB A vailable Capacity: 279.9375 MB [sp0]# [sp0]# ./sscs list pool Default Storage Pool: Default Description: Default Pool Storage Domain: DEFAULT Profile: Default Total Capacity: 545.23GB Allocated Capacity: 545.09GB Unallocated Capacity: 0.13GB VDisks: VDisk: disk/3/7/2/0/0 Status: Ok Volumes: Storage Arrays: Array: array01 Total Capacity: 545.2343 GB Configured Capacity: 545.0976 G B Available Capacity: 139.9687 MB [sp0]# [sp0]# ./sscs list vdisk disk/3/7/2/0/0 VDisk: disk/3/7/2/0/0 Storage Domain: DEFAULT Storage Pool: DBPRD_array01 Management: Internal Profile: ONI_RAID5_9D_64KB_1MB Tray: 0 Number of Disks: 9 Maximum Partitions: 32 Partitions Used: 3 Partitions Free: 29 State: In Use Status: Ok Total Capacity: 585440919552 Available Capacity: 146767872 Configured Capacity: 585294151680 Associated Volumes: Volume: PRD_ORA_0004 Volume: PRD_VOTING_0003 Volume: PRD_ORA_0003 [sp0]# Resolution The pool and profile configurations are stored in the file /opt/se6x20/resources/DspPersistence.xml inside the SP (Service Processor) and problems like the one in scope of this document is due to an inconsistency in the DspPersistence.xml file. If that happens, contact your Sun Technical Service Center for aid in fixing this issue. Additional Information Such problem has no impact to the data or their availability, this is just a "cosmetic" issue. Product Sun StorageTek 6920 System Internal Comments In order to solve such issue, the 6920 engineering team has to be engage and we have to provide them with a copy of the DspPersistence.xml file. Therefore, an escalation to TSC/PTS has to be raised. See the CR 6495418. 6920, pool, profile, DspPersistence.xml, vdisk, duplicate Previously Published As 87770 Change History Date: 2006-11-23 User Name: 71396 Action: Approved Comment: Publishing Version: 6 Date: 2006-11-22 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2006-11-22 User Name: 88218 Action: Approved Comment: Document is technically correct Version: 0 Date: 2006-11-22 User Name: 88218 Action: Accept Comment: Version: 0 Date: 2006-11-22 User Name: 71066 Action: Approved Comment: Added the following under the "Internal section": See the CR 6495418. Version: 0 Date: 2006-11-22 User Name: 71066 Action: Update Started Comment: Need to update it. Version: 0 Date: 2006-11-16 User Name: 71396 Action: Approved Comment: Performed final review of article Updated prouct name. Publishing. Version: 3 Date: 2006-11-15 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2006-11-15 User Name: 38107 Action: Approved Comment: looks good nicolas Version: 0 Date: 2006-11-14 User Name: 38107 Action: Accept Comment: Version: 0 Date: 2006-11-14 User Name: 71066 Action: Approved Comment: Hi, Please review this document. Thanks Nicolas Version: 0 Date: 2006-11-14 User Name: 71066 Action: Created Comment: Version: 0 Product_uuid 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System Attachments This solution has no attachment |
||||||||||||
|