Solution Type Problem Resolution Sure Solution 1005040.1 : Missing Sun StorEdge[TM] A1000 LUNs on bootup
PreviouslyPublishedAs 207093 Symptoms During the reboot of a system, not all of the LUN's of the A1000 will be visible to the system which will cause the system not to boot up completely or not mount any of the missing file systems. Sometimes, only one LUN will be missing. Other times, more LUN's can be missing. When this occurs, running devfsadm will bring all the LUN's back and then the file systems can be mounted manually. If a reboot -- -r or a boot -r is run, then all the LUN's will reappear. When all the LUN's are presented properly and the system is in operation there is generally no indication of SCSI or drive errors. Resolution The root cause of this problem is a missing or defective terminator. Replace or install a new terminator. Once the terminator has replaced or installed, verify that all the LUN's of the A1000 are seen. Use the format command to see what devices are available and compare it to the output of the /usr/sbin/osa/lad command. You should see the same number of LUN's from each of these commands. ie: root@marge# ./lad c1t5d0 1T04783042 LUNS: 0 1 2 3 4 5 6 <--- 7 LUN's format: AVAILABLE DISK SELECTIONS: 0. c0t0d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248> /pci@1f,4000/scsi@3/sd@0,0 1. c0t1d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248> /pci@1f,4000/scsi@3/sd@1,0 2. c1t5d0 <Symbios-StorEDGEA1000-0301 cyl 8615 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,0 3. c1t5d1 <Symbios-StorEDGEA1000-0301 cyl 8615 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,1 4. c1t5d2 <Symbios-StorEDGEA1000-0301 cyl 8615 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,2 5. c1t5d3 <Symbios-StorEDGEA1000-0301 cyl 8615 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,3 6. c1t5d4 <Symbios-StorEDGEA1000-0301 cyl 2046 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,4 7. c1t5d5 <Symbios-StorEDGEA1000-0301 cyl 2046 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,5 8. c1t5d6 <Symbios-StorEDGEA1000-0301 cyl 4519 alt 2 hd 64 sec 64> /pseudo/rdnexus@1/rdriver@5,6 Specify disk (enter its number): ^D This shows 7 A1000 LUN's. Relief/Workaround 1. run devfsadm
Product Sun StorEdge A1000 Array A1000, terminator, missing LUN, reboot Previously Published As 80015 Change History Date: 2005-02-18 User Name: 7058 Action: Approved Comment: No dups. Spell ck OK. Review date OK. Added Tmarks as needed. Restructured a few sentences for clarity. Bolded commands for clarity. Product_uuid 2a792916-0a18-11d6-8d0a-c3d03933af3c|Sun StorageTek A1000 Array Attachments This solution has no attachment |
||||||||||||
|