Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1004931.1 : Sun StorEdge[TM] 3510 Array: SES Firmware Upgrade Fails with sccli Error: sm_err_fw_download_failed
PreviouslyPublishedAs 206916 Symptoms SES Firmware Upgrade Fails with sccli Error: sm_err_fw_download_failed While upgrading 3510 Firmware with Patch ID 113723 , the RAID controller firmware upgrade completes but the SES firmware fails with the following error: sccli: download enclosure firmware: error: sm_err_fw_download_failed Logical disks (LD) then go to shutdown mode and a reset of the array is necessary to restart them. Here is the SES download: sccli> download ses-firmware fc2u_sun_1040a.s3r WARNING: This is a potentially dangerous operation. Are you sure? yes 4 SES Devices found SES # 1: CH 2 ID 12, INQ STR: SUN StorEdge 3510F A1040 SES # 2: CH 2 ID 28, INQ STR: SUN StorEdge 3510F D1000 SES # 3: CH 3 ID 12, INQ STR: SUN StorEdge 3510F A1000 SES # 4: CH 3 ID 28, INQ STR: SUN StorEdge 3510F D1000 sccli: download enclosure firmware: error: sm_err_fw_download_failed sccli> Resolution The problem is caused by having $PATH point to an older version of the sccli utility, installed with Store ADE. Before installing Patch ID 113723 firmware, check that the sccli version is correct by issuing the following command: # sccli sccli: selected device /dev/rdsk/c3t600C0FF000000000001EB21E6C045800d0s2 [SUN StorEdge 3510 SN#001EB2] sccli> ver sccli version 1.2.4 sccli> q # which sccli /opt/SUNWstade/bin/sccli This is pointing to the wrong version and will cause the error because the versions are incompatible. # which sccli /usr/sbin/sccli The above path is correct provided the version is 1.2.5 or later. It is strongly recommended that you use the version documented in the latest patch README. For 4.x firmware, obtain the latest 113723-xx patch which requires sccli version 2.4 or later. Relief/Workaround # /usr/sbin/sccli sccli> version sccli version 1.5.0 sccli> OR # /opt/SUNWsscs/sbin/sccli sccli> version sccli version 1.5.0 sccli> If you encounter the problem and LDs have shut down, you will need to reset the array. Additional Information Follow the below patch README with great care. [email protected] Patch ID 113723 Product Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Internal Comments For Internal Sun use only. The underlying problem is documented in Bug ID 4852573, "download firmware to ses devices fails and results in shutdown LDs". 3510 sccli SES sm_err_fw_download_failed, minnow, firmware, upgrade, 3511 Previously Published As 76732 Change History Date: 2004-06-08 User Name: C149439 Action: Approved Comment: Edited title and added trademark. Incorporated TR's suggestions. Copyedited text. Gail Waldron Version: 0 Date: 2004-06-08 User Name: C149439 Action: Accepted Comment: Version: 0 Attachments This solution has no attachment |
||||||||||||
|