Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1004684.1 : Raid Manager 6 error during bootup: The message definition file was not found
PreviouslyPublishedAs 206497 Symptoms When a Server is booted with any one of the Hardware RAID product arrays attached, Raid Manager (any version) is loaded on the system and will start up during the boot process. Included in the startup of Raid Manager is the execution of the /etc/init.d/amdemon script. When the script is executed, it will report the following error.... The message definition file was not found.c1t5d0s01T95126181 The message definition file was not found. The system completes its bootup and everything appears to be OK with RM6. Health check passes, luns are optimal and there is access to data. Resolution The error messages are generated when an nvutil command is executed from the /etc/init.d/amdemon script. The command is ... /usr/lib/osa/bin/nvutil -v -f The cause of the problem is with the /usr/lib/osa/messages.cat file. This binary file is either missing or corrupt. It appears to have a lot of the messages and dialogue pop-up strings you would see when administering RM6 from the GUI. The solution is to restore the file from backup or from the Raid Manager Media. Once restored, re-execute /usr/lib/osa/bin/nvutil -v -f command. You should see the expected output.... The NVSRAM settings of controller c1t5d0s0(1T95126181) are correct. nvutil command succeeded. Product N/A Sun StorageTek A1000 Array Sun StorageTek A3500 FC Array Sun StorageTek A3500 Array Internal Comments Previously Published As 27223 Change History Date: 2006-01-18 User Name: 31620 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-18 User Name: 31620 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2003-10-29 User Name: 13128 Action: Approved Comment: update okay - Publish Version: 0 Date: 2003-10-29 User Name: 87848 Action: Approved Comment: keywords/date edited-approving back into publish again Version: 0 Date: 2003-10-27 User Name: 71676 Action: Approved Comment: Keywords needed (RM6, Raid Manager) Exp. date updated, process verified. Version: 0 Date: 2003-10-16 User Name: 81292 Action: Unpublished Comment: Unpublishing so Mike can add more comments. Version: 0 Date: 2003-10-15 User Name: 13128 Action: Approved Comment: Update looks fine - Publish Version: 0 Date: 2003-10-15 User Name: 110334 Action: Approved Comment: Approved. Version: 0 Date: 2003-10-15 User Name: 71676 Action: Approved Comment: Update expiration date. Error and fix verified. Version: 0 Date: 2003-10-15 User Name: 71676 Action: Updated Comment: Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : George Bolduc comment : Reissuing since something went wrong with the first issue. date : Jun 26, 2001 updated by : Daniel Caporale comment : Article created. date : Jun 6, 2001 updated by : Daniel Caporale comment : No comment date : Jun 6, 2001 updated by : Howard Lapin comment : No comment date : Jun 6, 2001 updated by : Howard Lapin comment : No comment date : Jun 6, 2001 updated by : George Bolduc comment : Added title and rewrote some sentences for clarity. date : Jun 6, 2001 Version: 0 Product_uuid 00000000-0000-0000-0000-000000000000|N/A 2a792916-0a18-11d6-8d0a-c3d03933af3c|Sun StorageTek A1000 Array b648cdf0-efb8-4d4f-93d4-b17c1baf1935|Sun StorageTek A3500 FC Array 2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array Attachments This solution has no attachment |
||||||||||||
|