Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1004438.1
Update Date:2009-09-14
Keywords:

Solution Type  Problem Resolution Sure

Solution  1004438.1 :   Sun StorEdge[TM] A3x00 Array not seen when shared between two hosts.  


Related Items
  • Sun Storage A3000 Array
  •  
  • Sun Storage A3500 SCSI Array
  •  
  • Sun Storage A3500 FC Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
206132


Symptoms
A new Sun StorEdge A3x00 array, or one that has had the DacStore reset was connected up
between two hosts running Raid Manager 6.1.1, and the "independent controllers"
option was selected.
Raid Manager was then started up on both hosts, and the Configuration Manager
selected for each. Only one of the two systems was able to see the Array
properly and change the configuration, the other host had blank space where
the Array details should have been selectable.
The controllers were confirmed to be running in Active / Active mode, with the
latest firmware installed.


Resolution
From one of the hosts, start the Configuration Manager, and select the Raid
Module you are working with. Edit the Module Name, and apply this change. You
should see the name change in Raid Manager on both the connected hosts.

Next, reboot each host to allow the change to take effect.

This update to the Module should now have propagated through, and both hosts
should be able to access their respective controller modules correctly from
Raid Manager.

Product
Sun StorageTek A3500 Array
Sun StorageTek A3000
Sun StorageTek A3500 FC Array

Previously Published As
18403

Change History
Date: 2006-07-19
User Name: 71396
Action: Add Comment
Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=18403 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. ***
Version: 0
Date: 2006-01-18
User Name: 95826
Action: Update Canceled
Comment: *** Restored Published Content *** SSH AUDIT
Version: 0
Date: 2006-01-18
User Name: 95826
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : No owner
comment : Evaluated - Ross K
date : Jan 27, 1999
Version: 0
Product_uuid
2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array
2a7ca41a-0a18-11d6-82f2-e96014c515ea|Sun StorageTek A3000
b648cdf0-efb8-4d4f-93d4-b17c1baf1935|Sun StorageTek A3500 FC Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback