Solution Type  Problem Resolution Sure

Solution  1004023.1 :   Sun StorageTek[TM] 99x0: How to remove unwanted PLOGI (port login) with "reason=no connection"?  


Related Items
  • Sun Storage 9980 System
  •  
  • Sun Storage SAN Foundation Software
  •  
  • Sun Storage 9990V System
  •  
  • Sun Storage 9910 System
  •  
  • Sun Storage 9990 System
  •  
  • Sun Storage 9985V System
  •  
  • Sun Storage 9970 System
  •  
  • Sun Storage 9985 System
  •  
  • Sun Storage 9960 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Datacenter Disk
  •  
  • GCS>Sun Microsystems>Storage Software>Sun Storage SAN Software
  •  

PreviouslyPublishedAs
205613


Document reviewed for currency 09-May-2011

Symptoms
Hosts running Solaris[TM] Operating System connected to Sun StorageTek[TM] 99x0 (ST99x0) systems are reporting multiple PLOGI (Port login) with "reason=no connection":
Feb  6 10:10:46 hksu03 fp: [ID 517869 kern.info] NOTICE: fp(0): PLOGI to 11a00 failed state=Packet Transport error, reason=No Connection
Feb  6 10:15:46 hksu03 fp: [ID 517869 kern.info] NOTICE: fp(0): PLOGI to 11a00 failed state=Packet Transport error, reason=No Connection


Resolution
ST99x0 ports are connected to FC (Fibre Channel) switch and host can see ST99x0 ports and attempt to log into but failed during PLOGI process. In this case lun security is configured correctly to stop this host access.

To stop these unwanted PLOGI notices is to implement switch zoning and remove those unwanted ST99x0 ports from being seen by this host.

cfgadm -o show_FCP_dev -alv shows the lun as unconfigured failed
and luxadm -e dump_map shows the device as failed to get the type

cfgadm -o show_FCP_dev -alv
<snip>
c2::50060e800381da05           connected    unconfigured failed
unavailable  unknown      n    /devices/ssm@0,0/pci@18,600000/SUNW,qlc@1/fp@0,0:fc::50060e800381da05
luxadm -e dump_map
<snip>
4    11a00   0         50060e800381da05 50060e800381da05 Failed to get the type.

In cases where the host need access to the luns, then lun security would be required to configure and allow access by the host.



Product
Sun StorageTek SAN 4.0 Software
Sun StorageTek 9990V System
Sun StorageTek 9985V System
Sun StorageTek 9990 System
Sun StorageTek 9985 System
Sun StorageTek 9980 System
Sun StorageTek 9970 System
Sun StorageTek 9960 System
Sun StorageTek 9910 System
Sun StorageTek 9900V Series Array

Internal Comments
Esc # 1-16191931



SE99x0, SE9900, PLOGI, No Connection, failed to get the type, SAN, dump_map
Previously Published As
85194

Change History
Date: 2009-11-16
User Name: ehiguera
Action: Currency date.
Date: 2008-11-21
User Name: T230884
Action: Quality Review
Date: 2006-04-04
User Name: 97961
Action: Approved
Comment: - Applied trademarking
- Changed title to comply to the standard format
- Tidied up formatting
- Made simple sentence/grammatical corrections
Version: 3