Solution Type Problem Resolution Sure Solution 1004019.1 : Sun StorEdge[TM] 6320: Cannot create a volume
PreviouslyPublishedAs 205609 Symptoms On a Sun StorEdge[TM] 6320, 288GB of free space is available but any volume larger than 150GB cannot be created. In other words, only a subset of the available space can be mapped as a volume. Resolution The Sun StorEdge 6320 (applies to Sun StorEdge[TM] 6020 and Sun StorEdge[TM] 6120 as well) can only map contiguous space as one slice. Look at the output of volslice list in extractor: Slice Slice Num Start Blk Size Blks Capacity Volume census 0 0 734012928 350.003 GB tray0_pool1 - - 734012928 314565120 149.996 GB tray0_pool1 alak_vol_1 2 1048578048 1048578048 500.000 GB tray0_pool1 berk_vol_1 3 2097156096 1048578048 500.000 GB tray0_pool1 - - 3145734144 290204160 138.379 GB tray0_pool1 Notice there is an unmapped slice after the first one that is 149GB in size. At the end, the last slice has 138GB free. The Config service GUI will show this as 288GB free. However Configuration Service will fail when attempting to create a 288GB volume. There is no choice but to map the two non-contiguous slices separately. There is only one way to fix this. Delete all the volumes (only the two 500's actually) and restore everything from tape after recreating the volumes. The reason that only the 500GB volumes need to be deleted is that the free space will be contiguous afterwards. Relief/Workaround Concatenate the volumes with software RAID, either Veritas or Solstice DiskSuite[TM] on the host side. Product Sun StorageTek 6020 Array Sun StorageTek 6120 Array Sun StorageTek 6320 System Internal Comments
Article ID:
Service Request ID: 64941096 6020, 6320, 6120, sp, configuration service, gui Previously Published As 84913 Change History Date: 2006-03-21 User Name: 7058 Action: Approved Comment: Roger's requests have been implemented. Trademarking OK. Spell ck - fixed a few typos. Checked for duplicates - none located. Tags OK. OK to publish. Version: 4 Date: 2006-03-21 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2006-03-21 User Name: 71957 Action: Approved Comment: Fixed document per your suggestions. Version: 0 Date: 2006-03-21 User Name: 71957 Action: Add Comment Comment: Fixed per suggestions of final reviewer. Version: 0 Date: 2006-03-20 User Name: 97961 Action: Rejected Comment: Tasked performed on document during final review: - Changed title to comply to the standard format - Made simple sentence/grammatical corrections - Applied trademarking - Corrected Product meta-tagging In the process of doing the final review and making the document more customer friendly, I am faced the following difficulties in some of the original text: 1. The use of the term "vols". Is "vols" short for "volumes"? Or something else? Are end customers expected to understand the term "vols" when used in Sun's technical documentation/knowledge articles? 2. In the "Temporary Workaround" section, you stated "Concatenate them with software RAID, Veritas or SDS on the host side.". When you say "Concatenate them...", what does the "them" refer to? Is them = vols = volumes = slice? Please elaborate. Also, what is SDS (expand the acronymn)? Version: 0 Date: 2006-03-20 User Name: 97961 Action: Accept Comment: Version: 0 Date: 2006-03-20 User Name: 78962 Action: Approved Comment: Looks good. Version: 0 Date: 2006-03-16 User Name: 78962 Action: Accept Comment: Version: 0 Date: 2006-03-16 User Name: 71957 Action: Approved Comment: Please review Version: 0 Date: 2006-03-16 User Name: 71957 Action: Migrated Comment: apollo 1-15771305 2006-03-15 Version: 0 Product_uuid 5475c17c-c204-11d7-9de1-080020a9ed93|Sun StorageTek 6020 Array 2cd2e7d2-2980-11d7-9c3f-c506fe37b7ef|Sun StorageTek 6120 Array 4de60cc2-a08e-4610-b8bf-6a1881cb59c6|Sun StorageTek 6320 System Attachments This solution has no attachment |
||||||||||||
|