Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1003657.1
Update Date:2009-09-24
Keywords:

Solution Type  Problem Resolution Sure

Solution  1003657.1 :   Sun Fire[TM] V40z with multiple Cauldron-S card PCI slot placement limitations  


Related Items
  • Sun Fire V40z Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>x64 Servers
  •  

PreviouslyPublishedAs
205168


Symptoms
Placing Cauldron-S cards (4422A) in PCI Slots 2 and 3 leads to
SCSI reset errors that appear on both the cards. (PCI Slot 2 and 3)

Resolution
Place one Cauldron-S card in either PCI Slot 2 or 3. Other 4422A cards must be place in other six PCI slots.

Product
Sun Fire V40z Server

Internal Comments
See Bug Report 6196936 for more details on this issue.

V40z, Cauldron, PCI, 4422A, Cauldron-s, fiber, fibre
Previously Published As
81329

Change History
Date: 2005-05-04
User Name: 71396
Action: Approved
Comment: Peformed final review of article.

No changes required.

Publishing.
Version: 4
Date: 2005-04-27
User Name: 71396
Action: Accept
Comment:
Version: 0
Date: 2005-04-27
User Name: 121432
Action: Approved
Comment: Spell checked, information checked, added Bug Report reference and forwarded on to final review.
Version: 0
Date: 2005-04-27
User Name: 121432
Action: Accept
Comment:
Version: 0
Date: 2005-04-27
User Name: 135506
Action: Approved
Comment: MADE CORRECTION AS DIRECTED.
Ray
--------------------
Doc ID: 81329

Product(s): Sun Fire V40z Server

Tech Area(s): HBA (Host Bus Adaptor), Fibre Host Bus Adapter (HBA)

Tech Group: Volume Server Products (Low-end servers, misc. hardware)

Recipient Comment: Raymond,
You state it effects both nodes, are you referring to a cluster? If so your document does not say this, add it in. Does this happen when systems are not clustered?

Clarify the setup and any limitations for this document.

Thank you,
George
Version: 0
Date: 2005-04-27
User Name: 135506
Action: Add Comment
Comment: In the Technology Areas section, please remove Fibre Host Bus Adapter (HBA) because this Cauldron-S card is only card that is applicable. Thanks.
Version: 0
Date: 2005-04-27
User Name: 121432
Action: Rejected
Comment: Raymond,
You state it effects both nodes, are you referring to a cluster? If so your document does not say this, add it in. Does this happen when systems are not clustered?

Clarify the setup and any limitations for this document.

Thank you,
George
Version: 0
Date: 2005-04-27
User Name: 121432
Action: Accept
Comment:
Version: 0
Date: 2005-04-26
User Name: 135506
Action: Approved
Comment: This is associated with Bugster CR 6196936.
Version: 0
Date: 2005-04-26
User Name: 135506
Action: Created
Comment:
Version: 0
Product_uuid
4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.