Symptoms

When swapping the Sun StorEdge[TM] L9 Tape Autoloader tapelibrary FRU, it is possible that the library's controller is still configured for network access via the Remote Management Console (RMC) card. When no RMC is installed, the library will be partially available and the orange led on the front panel lit.

This can be resolved without the need of an RMC card.

Changes

{CHANGE}

Cause

{CAUSE}

Solution

Resolution
StorEdge[TM] L9 Tape Autoloader library PARTIAL AVAILABLE after swapping library

If, after a powercycle, the orange led is on and the library is PARTIAL AVAILABLE, use the front panel and the buttons below it to navigate through the menus :

[1] verify whether the RMC is the cause :

- main
- information
- loader information
- loader status

If it says :

      "PARTLY AVAILABLE"
"RMC not present"

then this infodoc applies.

[2] resolve the issue :

- main
- administration
- (default is 42311324)

A word of caution : it's possible that the L9 FRU still has the password of the former customer configured, in which case, you can reset the old password by applying the steps in internal .

- change configuration
- network access

following message will pop up :

      "cfg 'RMC Missing' Status"
"Reporting is ON"
"1. Suppress status report"

- choose 1 : suppress.



Additional Information
Only tested with L9 f/w revision 2.55 S



Internal Comments
Oracle Review 12/21/09, Glen Foley

L9 RMC PARTLY AVAILABLE, L9, Library Replacement, Swap, RMC, L9 Error
Previously Published As 79717

Change History
Date: 2004-12-21
User Name: 7058
Action: Approved
Comment: Updated format for easier reading.
Activated link to infodoc for easy reference.
OK to publish internal.
Review date updated.
Publish.
Version: 3
Date: 2004-12-21
User Name: 7058
Action: Accept
Comment:
Version: 0
Date: 2004-12-21
User Name: 37979
Action: Approved
Comment: I made some changes to the key words to help with searching.
Version: 0
Date: 2004-12-21
User Name: 37979
Action: Accept
Comment:
Version: 0