Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1003594.1 : StorEdge L9 - Tape Autoloader library PARTIAL AVAILABLE after swapping library
PreviouslyPublishedAs 205078
Applies to:Sun Storage L9 Tape LibraryAll Platforms Checked for relevance on 2-Feb-2011. SymptomsWhen swapping the Sun StorEdge[TM] L9 Tape Autoloader tapelibrary FRU, it is possible that the library's controller is still configured for network access via the Remote Management Console (RMC) card. When no RMC is installed, the library will be partially available and the orange led on the front panel lit.This can be resolved without the need of an RMC card. Changes{CHANGE}Cause{CAUSE}SolutionResolutionStorEdge[TM] L9 Tape Autoloader library PARTIAL AVAILABLE after swapping library If, after a powercycle, the orange led is on and the library is PARTIAL AVAILABLE, use the front panel and the buttons below it to navigate through the menus : [1] verify whether the RMC is the cause : - main - information - loader information - loader status If it says : "PARTLY AVAILABLE" "RMC not present" then this infodoc applies. [2] resolve the issue : - main - administration - A word of caution : it's possible that the L9 FRU still has the password of the former customer configured, in which case, you can reset the old password by applying the steps in internal - change configuration - network access following message will pop up : "cfg 'RMC Missing' Status" "Reporting is ON" "1. Suppress status report" - choose 1 : suppress. Additional Information Only tested with L9 f/w revision 2.55 S Internal Comments Oracle Review 12/21/09, Glen Foley L9 RMC PARTLY AVAILABLE, L9, Library Replacement, Swap, RMC, L9 Error Previously Published As 79717 Change History Date: 2004-12-21 User Name: 7058 Action: Approved Comment: Updated format for easier reading. Activated link to infodoc for easy reference. OK to publish internal. Review date updated. Publish. Version: 3 Date: 2004-12-21 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2004-12-21 User Name: 37979 Action: Approved Comment: I made some changes to the key words to help with searching. Version: 0 Date: 2004-12-21 User Name: 37979 Action: Accept Comment: Version: 0 Product_uuid 2ab212b2-0a18-11d6-9bdf-cd21504888a6|Sun StorageTek L9 Tape Autoloader Attachments This solution has no attachment |
||||||||||||
|