Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1003279.1 : Sun Fire[TM] V60x/Sun Fire[TM] V65x servers: Device probe fails to find any SCSI disks.
PreviouslyPublishedAs 204553 Symptoms You may experience one or more of the following symptoms when performing device probes and/or operating system installations on Sun Fire[TM] V60x/Sun Fire[TM] V65x servers. - Device probe using Device Configuration Assistant (Solaris[TM] x86 Platform Edition) (DCA) software fails to find any SCSI disks. - Device probe using DCA software finds the generic PCI RAID controller found instead of the onboard dual-channel Adaptec UW320 SCSI controller. - Linux installer fails to find any SCSI disks. Resolution BIOS steps to be performed Perform the following steps in order: 1. Power on the platform with a console connection attached. 2. The black and white POST/BIOS screen will appear. 3. When you are promoted by the "Adaptec BIOS" banner, press the keys <CTRL> <A> at the same time. 4. Navigate to "Configure/View Host Adapter Settings" (Menu system may differ depending on firmware revision of the Adaptec controller" 5. Turn OFF the "Adaptec HostRAID" function for BOTH channels. 6. Reboot the server. The above actions will adjust the PCI signature of the Adaptec controller which will correctly allow Adaptec drivers to bind to this device. The Adaptec HostRAID function is a Windows software RAID solution which presents multiple disk's as a single volume to a RAID specific driver. As Solaris and Linux do not utilize this specific driver, volumes will appear missing until Adaptec HostRAID is disabled. Additional Information The Sun Fire V60x/V65x servers ship from the factory with the "Adaptec HostRAID" function disabled. If this function has been enabled, the installation for Solaris and Linux may fail. Product Sun Fire V65x Server Sun Fire V60x Server Solaris 9 Operating System for x86 Platforms Red Hat Enterprise Linux 2.1 SuSE Linux Enterprise Server 8 x86 Software Red Hat Enterprise Linux 3 x86 Internal Comments For the internal use of Sun Employee's. A sales x-option for the actual RAID plugin card is required for the "Adaptec HostRAID" function to be activated. This x-option is not available as of 13-August-2003. Please check http://onestop/x86/sfv65xv60x.shtml for updates. v60x, v65x, solaris 9, DCA, x86, Adaptec, RAID, disk, probe, RedHat, Linux, installer Previously Published As 71135 Change History Date: 2009-11-27 User Name: 88029 Action: Updated Comment: Date: 2004-11-16 User Name: 71396 Action: Approved Comment: Reviewed document, updated product names and trademarking, publishing. Version: 3 Attachments This solution has no attachment |
||||||||||||
|