Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1003210.1 : How to read prtdiag memory interleaving on Ultra servers
PreviouslyPublishedAs 204407
Applies to:Sun Enterprise 3500 ServerSun Enterprise 4500 Server Sun Enterprise 5500 Server Sun Enterprise 6500 Server All Platforms SymptomsHow do I understand the prtdiag -v memory interleaving outputChanges{CHANGE}Cause{CAUSE}SolutionUltra Enterprise servers (UEXX00) have the ability to use memory interleaving. Memory interleaving can be viewed by the prtdiag command. /usr/platform/sun4u/sbin/prtdiag -vThe following explains how to read the prtdiag output. First you need to understand that you have possibility of 1-Way, 2-Way, 4-Way and 8-Way interleaving. In order to have any of the above memory interleaving groups, your memory boards must be the same size in each bank. Memory interleaving will group same size memory banks together. Your memory banks should be installed by installing them in bank 0 on all systems boards. Once ALL memory boards' bank0 are full then you should fill bank1 starting on memory board 0. Larger banks must be installed 1st for best performance. Below are several examples of prtdiag outputs.************************ EXAMPLE #1 *************************** ========================= Memory ========================= In the above example you have 12 banks all 1024MB in size. Since you have maximum possible 8-Way this will leave 4 more banks to have addition 4-Way. Thus group A = 8-Way and Group B = 4-Way. Memory Board# Memory Bank0 Memory Bank1 In this example you have 5 banks all the same size. So you will have 4-Way and 1-Way. The 1st group of 4-Way will be grouped using Bank 0 on all system boards. Then it will add bank1 from memory board 0 to complete a 4-Way. Leaving only 1 bank left will make a 1-Way on bank1 of board#2. Below you see how the system groups them. Memory Board# Memory Bank0 Memory Bank1 In this example you have 8 banks. But it will not group them in a single 8-Way bank because of the 2 difference sizes of banks. So the 4 banks of 1024MB will be a 4-way. Then the 4 banks of 256MB will be a 2nd 4-way. Below you can see how it groups them. Memory Board# Memory Bank0 Memory Bank1 Product Sun Enterprise 6500 Server Sun Enterprise 5500 Server Sun Enterprise 4500 Server Sun Enterprise 3500 Server Sun Enterprise 6000 Server Sun Enterprise 5000 Server Sun Enterprise 4000 Server Sun Enterprise 3000 Server Keywords: prtdiag, ultra servers, -v memory, interleaving Attachments This solution has no attachment |
||||||||||||
|