Applies to:Sun Storage C4 Tape LibraryVeritas NetBackup (NBU) Software - Version: 3.0 and later [Release: 3.0 and later] All Platforms Checked for relevance on 4-Jan-2011. SymptomsSymptomsA newly install Sun StorageTek[TM] C4 (aka Quantum PX500) tape library configure under Veritas Netbackup 6.0 only detects 20 out of 38 slots. The robtest utility in Veritas Netbackup Software also indicates only 20 slots available. (root)# /opt/openv/volmgr/bin/robtest Configured robots with local control supporting test utilities: TLD(0) robotic path = /dev/sg/c0tw100000e0022350e2l0 Robot Selection --------------- 1) TLD 0 2) none/quit Enter choice: 1 Robot selected: TLD(0) robotic path = /dev/sg/c0tw100000e0022350e2l0 Invoking robotic test utility: /usr/openv/volmgr/bin/tldtest -rn 0 -r /dev/sg/c0tw100000e0022350e2l0 Opening /dev/sg/c0tw100000e0022350e2l0 MODE_SENSE complete Enter tld commands (? returns help information) s s slot 1 (addr 256) contains Cartridge = no slot 2 (addr 257) contains Cartridge = no slot 3 (addr 258) contains Cartridge = no slot 4 (addr 259) contains Cartridge = no slot 5 (addr 260) contains Cartridge = no slot 6 (addr 261) contains Cartridge = no slot 7 (addr 262) contains Cartridge = no slot 8 (addr 263) contains Cartridge = no slot 9 (addr 264) contains Cartridge = no slot 10 (addr 265) contains Cartridge = no slot 11 (addr 266) contains Cartridge = no slot 12 (addr 267) contains Cartridge = no slot 13 (addr 268) contains Cartridge = no slot 14 (addr 269) contains Cartridge = no slot 15 (addr 270) contains Cartridge = no slot 16 (addr 271) contains Cartridge = no slot 17 (addr 272) contains Cartridge = no slot 18 (addr 273) contains Cartridge = no slot 19 (addr 274) contains Cartridge = no slot 20 (addr 275) contains Cartridge = no READ_ELEMENT_STATUS complete From the support.txt captured in the , we can clearly see all the 38 slots are been detected by Device Name : "/dev/sg/c0tw100000e0022350e2l0" Passthru Name: "/dev/sg/c0tw100000e0022350e2l0" Volume Header: "" Port: -1; Bus: -1; Target: -1; LUN: -1 Inquiry : "QUANTUM PX500 0005" Vendor ID : "QUANTUM " Product ID : "PX500 " Product Rev: "0005" Serial Number: "QP0617BDC00124" WWN : "" WWN Id Type : 0 Device Identifier: "QUANTUM PX500 QP0617BDC00124" Device Type : SDT_CHANGER NetBackup Robot Type: 8 Removable : Yes Device Supports: SCSI-2 Number of Drives : 1 Number of Slots : 20 Number of Media Access Ports: 18 <----- MAP set to 18 Drive 1 Serial Number : "HU10552GR4" Flags : 0x0 Reason: 0x0 Changes{CHANGE}Cause{CAUSE}SolutionResolutionPlease review the following information. The Sun StorageTek C4 tape library allow three different setting for Media Access Port /Load Port.
In order to change to None or No Media Access Port follow the steps below. Step 1 - Stop Netbackup /usr/openv/netbackup/bin/goodies/netbackup stop Step 2 - Change configuration setting on C4 OCP (Operator Control Panel) Select Setup
Return to the main menu on OCP Step 3 - Start Netbackup /usr/openv/netbackup/bin/goodies/netbackup start Step 4 - Confirm new setting with robtest /usr/openv/volmgr/bin/robtest Configured robots with local control supporting test utilities: TLD(0) robotic path = /dev/sg/c0tw100000e0022350e2l0 . . . slot 1 (addr 256) contains Cartridge = no slot 2 (addr 257) contains Cartridge = no slot 3 (addr 258) contains Cartridge = no . . . slot 36 (addr 291) contains Cartridge = no slot 37 (addr 292) contains Cartridge = no slot 38 (addr 293) contains Cartridge = no READ_ELEMENT_STATUS complete Product Sun StorageTek C4 Tape Library VERITAS NetBackup 6.0 VERITAS NetBackup 5.1 VERITAS NetBackup 5.0 Internal Comments Oracle review 11/5/09 Reference Case : 10942737 Reference Task : 22012552 StorageTek C4, Quantum PX500, Media Access Port, Load Port Previously Published As 87841 Attachments This solution has no attachment |
||||||||||||
|