Solution Type Problem Resolution Sure Solution 1002620.1 : Sun StorEdge[TM] 9985/9990: Partial parity group LDEV format is very slow
PreviouslyPublishedAs 203619 Symptoms Partial Parity Group LDEV formatting is extremely slow even when system option mode 269 (High Speed format) is on. Detail Description: As a comparison, using same sized LDEVs: Resolution The 9990/9985 subsystem is working as designed, the format speed control logic has not been changed in any microcode since the box was released and the slow formats experienced are not related to any hardware issues. An RFE to make partial parity group LDEV formatting run faster has been filed and accepted. Relief/Workaround Product Sun StorageTek 9990 System Sun StorageTek 9985 System Internal Comments For internal Sun use only. RFE: CR 6441966 Extremely slow partial parity group formatting Article ID: Service Request ID: 65052462 9990, 9985, slow, format, LDEV . Parity Group Previously Published As 86210 Change History Date: 2006-12-07 User Name: 71396 Action: Approved Comment: Performed final review of article. No changes required. Publishing. Version: 4 Date: 2006-12-06 User Name: 71396 Action: Accept Comment: Version: 0 Date: 2006-12-06 User Name: 18329 Action: Approved Comment: Changes as suggested Version: 0 Attachments This solution has no attachment |
||||||||||||
|