Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1002264.1 : Resolving Sun StorEdge[TM] A3500FC "Could not scan controllers" issue
PreviouslyPublishedAs 203189 Symptoms Manipulation of array controllers in rm6 is not allowed and the error Though rm6 cannot manipulate the controllers; LUN's do appear This problem can occur when more than 8 LUN's are configured Resolution If there are more than 8 LUN's configured on the array; ensure /etc/osa/rmparams is updated as follows: SystemMaxLunsPerController=16 (If there are more then 16 Luns then use 32) Run the following command: /usr/lib/osa/bin/genscsiconf After running genscsiconf, the host needs to be rebooted for the sd.conf to be reread allocating the additional lun support. This should be a reconfiguration reboot to create the additional device paths now visible from the extended lun support #touch /reconfigure #init 6 Check /dev/dsk and /dev/rdsk to ensure the additional luns device paths point to the rdnexus pseudo device and not to physical devices. Relief/Workaround none Additional Information none Product Sun StorageTek A3500 Array Internal Comments none rm6, a3500, a100, format, lad, contoller, "Could not scan controllers" Previously Published As 80338 Change History Date: 2006-07-19 User Name: 71396 Action: Add Comment Comment: *** This is an automatic message. This document has received 0 hits in Sunsolve in 60 days (see http://krep.emea.sun.com/stats/dochistory.cgi?docid=80338 ). If it does not receive any hit in the next 30 days, it will be automatically archived. See http://kmo.central.sun.com/VAM/ for further details. *** Version: 0 Date: 2005-02-18 User Name: 7058 Action: Approved Comment: Checked for dups-none located. Expanded > = "greater than" Enabled STM to offset preformatted text. Review date updated. OK to publish. Version: 3 Date: 2005-02-18 User Name: 7058 Action: Accept Comment: Version: 0 Date: 2005-02-18 User Name: 103982 Action: Approved Comment: Made some updates.. Sending back to workflow for final review Version: 0 Date: 2005-02-10 User Name: 103982 Action: Add Comment Comment: Updated procedure. If issue was truely Lun related and the array was using the sd driver. i.e. A3000 A3500 A1000 (not A3500FC which will use ssd). then the server will need to be rebooted to add the additional lun support. sd.conf gets read at boot. The reconfiguration option is necessary to build the device entries. Then you should check and ensure all the newly created device paths are pointing to rdnexus entries. Version: 0 Date: 2005-02-10 User Name: 103982 Action: Accept Comment: Version: 0 Date: 2005-02-10 User Name: 109161 Action: Approved Comment: ref case 64435004. based on onsite experience. could not find a solution in sunsolve. Version: 0 Date: 2005-02-10 User Name: 109161 Action: Created Comment: Version: 0 Product_uuid 2a8022d4-0a18-11d6-8043-ee5a180fdb7f|Sun StorageTek A3500 Array Attachments This solution has no attachment |
||||||||||||
|