Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1002112.1 : Sun Fire[TM] V100 and Sun Blade[TM] 150: timeout: reset target chno = 0 targ = 0 (Reference FCO A0228-1)
PreviouslyPublishedAs 203012 Oracle Confidential (INTERNAL). Do not distribute to customers Reason: Migrated distribution from Sun Symptoms This issue is related to FCO A0228-1. Sun Fire [TM] V100/Sun Blade[TM] 150 platforms may experience system timeout error Resolution If the 2 disks configuration involves Western Digital 40GB drives and SDS mirroring, apply FCO A0228-1. However, if it is a non mirrored configuration, and have verified that patch 108974-33 (or later) has been installed in the system, and if and only if the same timeout errors still appear, then use discretion to whether to replace the Western Digital 40GB drives with non Western Digital 40GB drives. If there is a replacement, it should be treated as a one off replacement, case by case basis, no mass swap. Replace 370-4419-xx or 370-4440-xx with 370-6626-01 (or above). *** IMPORTANT *** DO NOT replace these Western Digital 40GB drives in non-mirrored configuration when the timeout errors are NOT present. Product Sun Blade 150 Workstation Sun Fire V100 Server Internal Comments Reference FCO A0228-1. A0228-1, Sun Blade 150, Sun Fire V100, Western, Digital, Drive, XL40S/WD400BB, 370-4440-01 Previously Published As 80734 Change History Date: 2005-03-23 User Name: 111868 Action: Approved Comment: Verified Metadata Verified audience Checked review date Checked for TM Publishing Version: 4 Date: 2005-03-23 User Name: 111868 Action: Accept Comment: Version: 0 Date: 2005-03-22 User Name: 89705 Action: Approved Comment: I have rephrased the sentances from the document to make it more readable. I have removed the comment from the additional info. If you wished to have the FCO A0228-1 changed or amended, this is NOT the place for you to do it. Send your business and technical justifications to the FINFCO review team for review on why there is a need to have the FCO amended. Version: 0 Date: 2005-03-21 User Name: 89705 Action: Accept Comment: Version: 0 Date: 2005-03-16 User Name: 129400 Action: Approved Comment: this document is important! Version: 0 Date: 2005-03-16 User Name: 31620 Action: Reassign Comment: Hi Yasuyuki, I have released the document back to you so that you can add the edits you want to and send it straight to FR when you are done. Andy MacBain Knowledge Operations Version: 0 Date: 2005-03-16 User Name: 129400 Action: Approved Comment: This contents is important. Version: 0 Date: 2005-03-16 User Name: 129400 Action: Created Comment: Version: 0 Product_uuid 528e68a2-65c2-404c-9499-58d4834cd4d0|Sun Blade 150 Workstation 2a071da8-0a18-11d6-906c-a8efc43ec293|Sun Blade 100 Workstation Attachments This solution has no attachment |
||||||||||||
|