Solution Type  Problem Resolution Sure

Solution  1002099.1 :   Sun Fire[TM] V440: Unable to create a 2nd RAID1 volume  


Related Items
  • Sun Fire V440 Server
  •  
  • Sun Netra 440 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>NEBS-Certified Servers
  •  
  • GCS>Sun Microsystems>Servers>Entry-Level Servers
  •  

PreviouslyPublishedAs
202948


Symptoms
When trying to create a 2nd RAID1 volume using the internal RAID controller, the
raidctl command fails with the following error message;

% raidctl -c c1t2d0 c1t3d0
RAID Volume already exists on this controller 'c1t0d0'

Resolution
The Product documentation states that you can create a RAID1 volume with any 2
internal disks. The system can hold a maximum of 4 internal disks however, this doesn't mean you can create 2 RAID1 volumes.

The Internal RAID controller supports ONLY A SINGLE RAID1 volume.
So it is not possible to create a second raid 1 with the same controller using
raidctl utility.

Additional Information
You can mirror additional disks using Solaris[TM] Volume Manager software
included in Solaris[TM] 9.

Product
Sun Fire V440 Server
Sun Fire V440R Server
Netra 440 Server

V440, raidctl, raid1, RAID Volume
Previously Published As
73595

Change History
Date: 2009-11-30
User Name: Anthony Rulli
Action: Updated
Comment: currency check, audited by Anthony Rulli, Entry Level SPARC Content team

Date: 2006-01-23
User Name: 25440
Action: Update Started
Comment: SSH AUDIT
Version: 0
Date: 2005-03-29
User Name: 97961
Action: Approved
Comment: Publishing.
Version: 6

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback