Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1001954.1
Update Date:2009-09-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  1001954.1 :   Sun StorEdge[TM] 6320 System: "IO Error accessing persistence file on flash disk"  


Related Items
  • Sun Storage 6320 System
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - 6xxx Arrays
  •  

PreviouslyPublishedAs
202721


Symptoms

The following error message, or a similar error, appears every two minutes
on the Sun Fire[TM] V100 Server's Service Processor (SP) of the Sun StorEdge
6320 system:

        "IO Error accessing persistence file on flash disk" 


Resolution

The flash disk, Part # 370-5773, is a USB (Universal Serial Bus) device
that plugs in to the back of the Sun Fire V100 and is used to store the
configuration files.

The error above indicates that the flash disk might be faulty, missing, or
not seated properly.

To troubleshoot this problem, do the following:

1. Reseat the USB device.
2. If you are still getting the same error, log in to the SP and check that
/flash is NOT mounted. 
 NOTE:
 /flash should only be mounted by the fbr script. With /flash mounted,
the fbr script will not be able to execute.
3. If /flash is mounted, umount /flash. This should clear the error.
4. If the error persists, rebuild the operating system of the Sun Fire V100
using the recovery CD.
It is possible that a software problem on the SSP can cause the flash disk to
be inaccessible. 


Additional Information

The error may also take different forms as below :

persist.1:PERSISTENCE_IO_ERROR:0:IO Error accessing persistence
file on flash disk

persist.2:PERSISTENCE_IO_ERROR_ON_FILE:1:Error accessing persistence
data file {0}:

persist.3:PERSISTENCE_IO_ERROR_ON_STORAGE:0:Error accessing persistence
flash disk



Product
Sun StorageTek 6320 System

6320, USB flash disk, V100, Service Processor, SP, Maserati
Previously Published As
76875

Change History
Date: 2004-08-23
User Name: 91361
Action: Approved
Comment: KE'd ... ready to publish.

- KE, Matt Steck, x79938
Version: 2
Date: 2004-08-23
User Name: 91361
Action: Accept
Comment:
Version: 0
Date: 2004-08-20
User Name: 26402
Action: Approved
Comment: Made minor changes to grammar and structure.
Simplified examples of error messages.
Version: 0
Date: 2004-07-20
User Name: 26402
Action: Accept
Comment:
Version: 0
Date: 2004-06-24
User Name: 79348
Action: Approved
Comment: verified , re-submitting
Version: 0
Date: 2004-06-18
User Name: C149439
Action: Rejected
Comment: Hi. I'm returning your doc so you can confirm accuracy. I've created a procedure from text to make information more accessible. Also, I've spelled out acronyms and product names, and added trademarks. Tks. Gail Waldron
Version: 0
Date: 2004-06-16
User Name: C149439
Action: Accepted
Comment:
Version: 0
Date: 2004-06-15
User Name: 38107
Action: Approved
Comment: Doc
Version: 0
Date: 2004-06-15
User Name: 38107
Action: Accepted
Comment:
Version: 0
Date: 2004-06-14
User Name: 79348
Action: Approved
Comment: Pls review , this seems to be a common call generator .
Version: 0
Date: 2004-06-14
User Name: 79348
Action: Created
Comment:
Version: 0
Product_uuid
4de60cc2-a08e-4610-b8bf-6a1881cb59c6|Sun StorageTek 6320 System

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.