Solution Type Problem Resolution Sure Solution 1001761.1 : Sun StorEdge[TM] 9900 Series Remote Console does not accept password after installation.
PreviouslyPublishedAs 202402 Symptoms Remote Console doesn't accept default USER and p/w=USER after initial installation. Missing file C:\Hirmc\com\user.lst Resolution 1) De-Install RMC (Remote Console) then make a fresh installation from diskette or CD ROM using exactly the method in the RMC manual. That is, using the Windows Start>Run... and enter source drive:\setup.exe or 2) Copy the file from source drive:\config\com\ to c:\hirmc\com\ Product Sun StorageTek 9910 Sun StorageTek 9980 System Sun StorageTek 9970 System Sun StorageTek 9960 System Internal Comments Contributed by [email protected] Previously Published As 43200 Change History Date: 2006-01-25 User Name: 7058 Action: Update Canceled Comment: *** Restored Published Content *** ssh audit Version: 0 Date: 2006-01-25 User Name: 7058 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2006-01-25 User Name: 7058 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT Version: 0 Date: 2006-01-25 User Name: 7058 Action: Update Started Comment: SSH AUDIT Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : George Bolduc comment : Article created. date : Feb 27, 2002 updated by : George Bolduc comment : Transferred from Fatwire date : Feb 27, 2002 Version: 0 Product_uuid 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 c2428fbe-8ab7-41d0-8b6e-ab489823c9d4|Sun StorageTek 9980 System 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System Attachments This solution has no attachment |
||||||||||||
|