Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1001760.1 : Sun StorEdge[TM] T3 - Warning: Device has not been removed from the slot and is still in the loop map
PreviouslyPublishedAs 202401 Symptoms When trying to physically remove a Sun StorEdge T3 Disk Tray from a server using luxadm, the following error message is reported.: # luxadm remove_device [-F] <WWN T3 > "Device: <pathname> Warning: Device has not been removed from the slot and is still in the loop map." This error is reported after physically removing the T3 and hitting <Return>: Resolution 1. # luxadm remove_device -F <WWN T3> 2. Once the prompt tells you to remove the device, and you hit <Return>, telnet into the Sun StorEdge T3 Disk Tray and unmount all volumes 3. On the server performing the luxadm remove_device command, hit <Return> to remove the device paths from the OS. Product Sun StorageTek T3 Array Internal Comments See Also: Bug ID <BugID>4410483</BugID> Previously Published As 41697 Change History Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Wendy Bean comment : No comment date : Mar 1, 2002 updated by : Sophia Hill comment : Article created. date : Nov 28, 2001 updated by : Sophia Hill comment : No comment date : Nov 28, 2001 updated by : Matthew Teeter comment : No comment date : Nov 28, 2001 Version: 0 Product_uuid 2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array Attachments This solution has no attachment |
||||||||||||
|