Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Problem Resolution Sure Solution 1001698.1 : Sun StorEdge[TM] 9900:Symptom:JNI - "Memory Port Parity Error Detected" causes link to go offline and online
PreviouslyPublishedAs 202310 Symptoms While attempting to transfer large amounts of data from a 99x0 to a Fiber Tape Library during a backup, a parity error was detected and it forced the link offline. Further testing showed transfering large files from the 99x0 to a local filesystem on the host also produced the errors. The errors appear as follows: Jan 18 13:19:23 mactivebk jnic: [ID 847178 kern.notice] jnic1: Memory port parity error detected Jan 18 13:19:23 mactivebk jnic: [ID 229844 kern.notice] jnic1: Link Down Jan 18 13:19:23 mactivebk jnic: [ID 790760 kern.notice] jnic1: Target0: Port 011100 (WWN 500060E802EC9F00:500060E802EC9F00) offline. Jan 18 13:19:23 mactivebk jnic: [ID 940895 kern.notice] jnic1: Target1: Port 011300 (WWN 500060E802EC9F10:500060E802EC9F10) offline. Jan 18 13:19:23 mactivebk jnic: [ID 934265 kern.notice] jnic1: Target2: Port 011700 (WWN 100000E00201F4B2:100000E00221F4B2) offline. Jan 18 13:19:27 mactivebk jnic: [ID 709123 kern.notice] jnic1: Link Up Jan 18 13:19:28 mactivebk jnic: [ID 941442 kern.notice] jnic1: Target0: Port 011100 (WWN 500060E802EC9F00:500060E802EC9F00) online. Jan 18 13:19:28 mactivebk jnic: [ID 345876 kern.notice] jnic1: Target1: Port 011300 (WWN 500060E802EC9F10:500060E802EC9F10) online. Jan 18 13:19:28 mactivebk jnic: [ID 651312 kern.notice] jnic1: Port 011700 supports FCP-2 error recovery. Jan 18 13:19:28 mactivebk jnic: [ID 282924 kern.notice] jnic1: Target2: Port 011700 (WWN 100000E00201F4B2:100000E00221F4B2) online. Resolution An email to JNI's support alias gave the following information: "The memory port parity error can be fixed by entering this parameter into your jnic.conf file: FcEnableContextSwitch = 1; You will have to reboot the system in order for the modifications to take effect. If this does not prevent the error messages, then it is likely a defective HBA." After making the change the errors no longer occured, however, while performing large file transfers the system then panicked. With Kernel's assistance, the modifications were made to /etc/system. The stack size was changed from 0x4000 to 0x6000. set lwp_default_stksize=0x6000 set rpcmod:svc_default_stksize=0x6000 Also, the FcEnableContextSwich parameter was added into /kernel/drv/jnic.conf for each JNI Adapter: jnic0-FcEnableContextSwitch=1; jnic1-FcEnableContextSwitch=1; Product Sun StorageTek 9960 System Sun StorageTek 9910 Sun StorageTek 9970 System Internal Comments Case 63364487 Sun Fire 4800 connected to a SAN (not sure about which switch). 9960 connected to switch along with an STK L40 via an STK 3250 SCSI-Fiber Bridge Netbackup 4.5 patched, recently added the /kernel/drv/st driver patch which may have aided in the solution. [email protected] Previously Published As 50406 Change History Date: 2006-01-18 User Name: 97961 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT. [email protected] KDO Knowledge Engineer Version: 0 Date: 2006-01-18 User Name: 97961 Action: Update Started Comment: SSH AUDIT. [email protected] KDO Knowledge Engineer Version: 0 Date: 2006-01-18 User Name: 97961 Action: Update Canceled Comment: *** Restored Published Content *** SSH AUDIT. [email protected] KDO Knowledge Engineer Version: 0 Date: 2006-01-18 User Name: 97961 Action: Update Started Comment: SSH AUDIT. [email protected] KDO Knowledge Engineer Version: 0 Date: 2003-05-20 User Name: Administrator Action: Migration from KMSCreator Comment: updated by : Dean Clausen comment : need to correct permissions date : Feb 3, 2003 updated by : Dean Clausen comment : Trademark and title work applied - Issued date : Feb 3, 2003 updated by : Matthew Teeter comment : No comment date : Jan 30, 2003 updated by : Matthew Teeter comment : No comment date : Jan 30, 2003 updated by : Brian Barbe comment : Article created. date : Jan 29, 2003 updated by : Brian Barbe comment : No comment date : Jan 29, 2003 updated by : Juliana Ryan comment : No comment date : Jan 29, 2003 Version: 0 Product_uuid 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System Attachments This solution has no attachment |
||||||||||||
|