Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1307224.1 : RW2 SIM heartbeat timeout (aka White Light Special) scenario with RW2, which will cause one of the SIMs to go offline and show up as one of the paths to the JBOD removed.
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun ZFS Storage 7320 - Version: Not Applicable to Not Applicable - Release: N/A to N/ASun Storage 7410 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun ZFS Storage 7120 - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun Storage 7310 Unified Storage System - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun ZFS Storage 7420 - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Information in this document applies to any platform. __________ SUNBUG: 7017185 Affected Parts: 542-0194 - Disk Shelf 24x3.5" SAS-2 Interface Module (SIM) SymptomsThe SIM may only have one path to devices attached to it and the White "Locate" LED illuminates. Also the Service LED right above it turns to a constant and solid Amber color. On the front of the JBOD, the "Serve LED" on the left hand side is on solid and the "Rear SIM" LED illuminates with a solid light.Impact SIM heartbeat timer expires. RW2 will show as degraded, SIM will go offline due to heartbeat timeout. ChangesAfter checking the health of any of the above listed systems (ensuring that all devices in a DiskShelf unit, including the SIMs, have dual paths to all) one of the SIMs may only have one path to devices attached to it and the White "Locate" LED is illuminated. Also the Service LED right above it turns to a constant Amber color. On the front of the JBOD, the "Service LED" on the left hand side is on solid and the "Rear SIM" LED illuminates with a solid light.CauseThe Heartbeat timer between the two SIMs expires.The formal fix will be the distribution of a new Diskshelf SIM FW. SolutionWorkaroundReseating of the SIM board that has the White "Locate" LED lit will work around this issue. Resolution Please perform the following steps to alleviate this situation: 1) Pull the failed SIM from the chassis 2) Wait two minutes 3) Plug the SIM back into the chassis 4) Wait for it to come back online (Green "Ready" LED will light) Repeat these steps for all other SIMs that may have this fault signature in other JBODs. References BugID: 7017185 Pending Patches: Q3.4 Resolution Patches: Q3.4 Contacts Contributor: [email protected] Responsible Engineer: [email protected] Responsible Manager: [email protected] Business Unit Group: NWS (Network Storage) For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: https://sunspace.sfbay.sun.com/display/Onestop/FAB%20(Field%20Action%20Bulletin) In addition to the above you may email: * [email protected] Attachments This solution has no attachment |
||||||||||||
|