Solution Type FAB (standard) Sure Solution 1266267.1 : Sun Flash F5100 ASR Activation will not work with CAM version 6.6 or lower.
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun Flash F5100 Array - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. __________ SUNBUG 6950805 Affected Parts: 541-3143 - Motherboard Assembly 501-7696 - Power Distribution Board SymptomsThe customer will only notice that the ASR activiation process did not complete. The ASR internal SAMs server will note the customer activation did not complete, with the following error message given, "Investigation - Serial not found".Impact Customer will encounter that Auto Service Request (ASR) will not complete the activation process during ASR set-up while a F5100 Array is managed with CAM version 6.6 or lower. The customer may incorrectly believe their F5100 Array is being monitored. ChangesContributing FactorsCommon Array Manager (CAM) version 6.6 (or below) running one of the following Sun Flash F5100 Array configurations:
CauseRoot CauseCAM version 6.6 (or lower) pulls the motherboard assembly WWN. ASR expects the system serial number, which is programmed within the power distribution board assembly and is physically located on the F5100 front left bezel. SolutionWorkaroundNo workaround available - see Resolution section below. Resolution Customer must install CAM version 6.7 (or greater), which pulls the expected system serial number found on the power distribution board assembly. This will allow the ASR activation process to complete successfully. CAM 6.7 can be found at the below URL; http://www.sun.com/storage/management_software/resource_management/cam/get_it.jsp References SUNBUG 6950805 For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: * http://tns.central/fab In addition to the above you may email: * [email protected] @ Contacts @ Contributor: [email protected] @ Responsible Engineer: [email protected] @ Responsible Manager: [email protected] @ Business Unit Group: [email protected] @ NWS (Network Storage) Attachments This solution has no attachment |
||||||||||||
|