Solution Type FAB (standard) Sure Solution 1020831.1 : Netra T5440 with firmware 7.1.8.c or 7.2.1.d sometimes produces erroneous voltage threshold warnings.
PreviouslyPublishedAs 265651 Bug Id <SUNBUG: 6848139> Product Sun Netra T5440 Server Date of Resolved Release 12-Aug-2009 T5440 produces unwarranted warning messages (see details below). ImpactSun Netra T5440 can produce warning messages when no hardware problem exists. This issue does not impact system operation in any way.Contributing FactorsThis issue impacts AC powered Netra T5440 systems with firmware 7.1.8.c or 7.2.1.d (or earlier).SymptomsThe system produces the following warning message when no problem exists;"V_VCORER at /SYS/MB has exceeded high warning threshold" This error will show on the Console and in the ILOM Event Log. Root CauseVCORE data for ILOM is taken from the adm1026 measurement of the converter output. Through this method there is an error introduced into the data. The adm1026 can have approximately 20mV of error, and measuring VOUT versus VSENSE (voltage actually seen by the CPU) introduces another 40+mV of discrepancy depending on the load and IR drop across the board. These combine to produce enough of an offset to trigger a warning message.Systems will continue to ship in the short term with firmware 7.1.8.c, but will eventually switch to a version of 7.2.2.x. Corrective ActionWorkaround:No workaround available - see Resolution section below. Resolution: Upgrade firmware to 7.1.8.d or 7.2.2.e (or above). For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: For Sun Authorized Service Providers go to: In addition to the above you may email: Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Responsible Manager: [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group SSG NSN (Netra Systems and Networking) Internal Sun Alert & FAB Admin Info 10-Aug-2009: Completed draft and sent to Extended Review. 12-Aug-2009: No feedback from Ext Rvw - sending to Publish. Attachments This solution has no attachment |
||||||||||||
|