Solution Type  FAB (standard) Sure

Solution  1020470.1 :   Unified Storage Systems 7110, 7210, 7410 do not have a system board FRU for replacement.  


Related Items
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Sun Storage 7410 Unified Storage System
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
259068


Bug Id
<SUNBUG: 6841465>

Product
Sun Storage 7110 Unified Storage System
Sun Storage 7210 Unified Storage System
Sun Storage 7410 Unified Storage System

Date of Preliminary Release
15-May-2009

Unified Storage Systems 7110, 7210, 7410 do not have a system board FRU for replacement.

Impact

In the event that a Sun Storage 7110, 7210, and 7410 Unified Storage Systems has a system board
failure there is no replacement FRU. There is no way to do a replacement at this time.

All such issues need to be escalated prior to attempting to fix.

Contributing Factors

This issue impacts the following system boards:

- 7110 System Board P/N 541-2297
- 7210 System Board P/N 541-3241
- 7410 System Board P/N 541-2297

Note:  The Unified Storage Series 7000 use special onboard settings not available on the system boards
for the base servers. Without these settings the system will malfunction. The use of system boards associated
with the base X64 Servers (Sun Fire X4240, X4540 or X4440) will cause detrimental damage to the system
and under no condition should be used.


Symptoms

Any apparent system board related failure.

Root Cause

The tools to apply the board setting in the field are under development but not available at this time. 

Corrective Action

Workaround

If a system board appears suspect then the issue needs to be escalated prior to attempting to fix.

Escalate to the following team and persons:

    Storage NAS

Zuheir Totari
AMER [email protected]
EMEA [email protected]
APAC [email protected]

They have procedures in place to deal with such situations.


Resolution

A final resolution is pending completion.

An estimated date for resolution is September 2009.



References

BugID:  6841465
These CRs are closed without fix: 6811880, 6829776, 6830935




For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL:

For Sun Authorized Service Providers go to:

In addition to the above you may email:


Internal Contributor/submitter
[email protected]

Internal Eng Responsible Engineer
Zuheir Totari AMER [email protected] EMEA [email protected] APAC [email protected] Responsible Managers: AMER [email protected] EMEA [email protected] APAC [email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Eng Business Unit Group
NWS (Storage)

Internal Sun Alert & FAB Admin Info
13-May-2009, karen, the draft was submitted 08 May 2009. i am sending for 2 day review today.

Internal Sun Alert & FAB Admin Info
13-May-2009, karen, the draft was submitted 08 May 2009. i am sending for 2 day review today.
19-Nov-2009: Corrected Product Name to swoRDFish inconsistency.


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback