Solution Type FAB (standard) Sure Solution 1020158.1 : Chipkill not working within the BIOS on V20z and V40z platforms.
PreviouslyPublishedAs 253247 Bug Id <SUNBUG: 6690972> Product Sun Fire V20z Server Sun Fire V40z Server Date of Resolved Release 20-Feb-2009 Chipkill not working within BIOS on V20z / V40z (see details below). ImpactUnexpected reboots and/or hangs may occur on the V20z/V40z with AMD Dual Core Opteron Processors as a result of the Chipkill feature not working properly within the BIOS.Contributing FactorsThis issue impacts software updates and NSV versions prior to Sun Fire V20z/V40z Server SW 2.8.2.SymptomsSystems can reboot and/or hang with no specific error messages displayed in the log files.Root CauseConfirmed that this issues exists in all Software updates and NSV versions prior to Sun Fire V20z/V40Z Server SW 2.8.2.Corrective ActionWorkaround:No workaround available - see Resolution section below. Resolution: A new BIOS has been created to correct the chipkill function: Sun Fire V20z/V40z Server SW 2.8.2. Recommend all customers that have V20z/V40z servers with AMD Dual Core Opteron Processors install the new Sun Fire V20z/V40z Server SW 2.8.2. The only change from the previous Sun Fire V20z/V40z Server SW 2.8 version is that chipkill is now enabled. V20z/V40z Server SW 2.8.2 (or above) can be found via the below URLs; V20z: http://www.sun.com/servers/entry/v20z/downloads.jsp V40z: http://www.sun.com/servers/entry/v40z/downloads.jsp CommentsIn order to successfully install the chipkill fix, please install the sp firmware from Sun Fire V20z/V40z Server SW 2.8 followed by installing the bios firmware from Sun Fire V20z/V40z Server SW 2.8.2 (or above). When installed correctly the sp version will be 2.4.0.20 (or above) and the bios version will be either V20z BIOS version 1.35.5.1 or V40z BIOS version 2.35.5.1.For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: For Sun Authorized Service Providers go to: In addition to the above you may email: Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Responsible Manager: [email protected] Internal Eng Business Unit Group NSG (Network Systems Group) Internal Sun Alert & FAB Admin Info 18-Feb-2009: completed draft and sent to Extended Review. 21-Feb-2009: Modified per Ext Rvw feedback - sending to Publish. Attachments This solution has no attachment |
||||||||||||
|