Solution Type  FAB (standard) Sure

Solution  1019624.1 :   FCO A0296-1: Sun External I/O Expansion Unit Fiber Optic Link Card fails after 500 power-on days.  


Related Items
  • Sun External I/O Expansion Unit
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Hardware Remediation>Mandatory
  •  

PreviouslyPublishedAs
242506


Product
Sun SPARC Enterprise M4000 Server
Sun SPARC Enterprise M5000 Server
Sun SPARC Enterprise M8000 Server
Sun SPARC Enterprise M9000 Server
Sun External I/O Expansion Unit

Date of Resolved Release
13-Oct-2008

Optical transmitter on Fiber Optic Link Card fails after 500 power-on days (see details below).

Affected X-Options:
 
SENX8LK2Z
SENX8LK3Z
 
Affected Parts:
 
501-7040-06 (or below)   Fibre Link Card

Impact

Domain failure which can only be corrected by replacement of the Fibre Link Card (Sun P/N 501-7040).  These cards will fail after 500 days power-on days, including test time.

Contributing Factors

Above listed systems having a Fibre Link Card (Sun P/N 501-7040-06 or below) are impacted by this issue.

Symptoms

The optical transmitter used on the Sun External I/O Expansion Unit Fiber Optic Link Card fails after 500 power-on days.  Failure of the optical transmitter results in domain failure.

Root Cause

During the transition to RoHS6 compliance, Sun's supplier changed from an on-board based EEPROM to a packaged EEPROM.  This changed the capacity from 32k bytes to 4k bytes.  The aging factor which is loaded into EEPROM age block was not modified to account for the smaller capacity.  This will shutdown the part after 500 power-on days, including test time.

Product was put on StopShip, and Manufacturing inventory purged via SSP# P001-20512, until 501-7040-07 was released via ECO# WO_39114 as of April 28, 2008.  Services initiated a purge via GSAP 4308 as of May 14, 2008.

Corrective Action

Target Completion Date: July 17, 2009
 
Workaround:

No workaround available - see Resolution section below.
 
Resolution:
 
Proactively contact all affected customers of record and replace the 501-7040-06 (or below) with 501-7040-07 (or above).

A Customer Letter has been made available via the below URL;

  http://sdpsweb.central/FIN_FCO/FCO/A0296-1/SPE/FCO296-Customer_Letter.sxw

Note: It is important that you read the COMMENTS section below.

Identification of Affected Parts (how to):

Reference the Affected Customer List via SunFIT per the below URL;

  http://sunfit.central.sun.com/login

Hardware Remediation and Material Availability Details:

At the time of publication limited material was available in most Regions.  Check with your Logistics Representative or TZ / Country / Area FCO Manager for more information with regard to material availability and the parts ordering process for this FCO.


Note to Authorized Service Partners:

Sun Authorized Service Partners may contact Sun Services or their Sun Services Representative to receive FAB related information, including Customer details.

Comments

It is imperative that affected systems are remediated in order of their priority, as listed in SunFIT.  Priority 1 systems will fail in the October/November time frame.  As a guideline, remediate the affected system, by priority, no more than a month before they reach 500 days from their ship date.  Ship dates may be viewed in the system S/N details in SunFIT.

Priority 1    500 days = Oct/08 - Nov/08
Priority 2    500 days = Dec/08 - Jan/09
Priority 3    500 days = Feb/09 - Mar/09
Priority 4    500 days = Apr/09
Priority 5    500 days = May/09 - Jun/09
Priority 6    500 days = Jul/09 - Oct/09

Failure to follow these guidelines may result in other Customer outages when they reach the 500 day threshold and parts are not available to remediate their affected systems.

References:
 
  ECO: WO_39114
  GSAP: 4308
  WW Stop Ship: P001-20512
  Sun Alert: 243446


For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL:

For Sun Authorized Service Providers go to:

In addition to the above you may email:


Internal Contributor/submitter
[email protected]

Internal Eng Responsible Engineer
[email protected] Responsible Manager: [email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Eng Business Unit Group
SSG ES (Enterprise Systems)

Internal Sun Alert & FAB Admin Info
23-Sep-2008: Finalized draft - awaiting Material Readiness - sent to Tiger Team for final review.
13-Oct-2008: Material Readiness achieved and SunFIT ready - sending to Publish.
02-Dec-2009: Corrected Product Name to swoRDFish inconsistency.


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback