Solution Type FAB (standard) Sure Solution 1019609.1 : ILOM 2.0.2.5 on Sun Fire x4500 may alter Solaris disk names.
PreviouslyPublishedAs 242206 Bug Id <SUNBUG: 6724613>, <SUNBUG: 6725713> Product Sun Fire X4500 Server Date of Resolved Release 19-Sep-2008 ILOM 2.0.2.5 may alter Solaris disk names (see details below). ImpactAfter upgrading the ILOM on a Sun Fire X4500 to 2.0.2.5, if Solaris is reinstalled, and if the virtual CDROM and virtual floppy devices are not mapped in the JavaRConsole, several of the Solaris disk names may change. On newer systems shipped from the factory with ILOM 2.0.2.5 preinstalled, you may notice the boot disk and several other disks have different Solaris disk device names than prior shipped systems. This may cause confusion to the customer or the field.Contributing FactorsSun Fire X4500 upgraded to ILOM 2.0.2.5 may be impacted by this issue.This is a result of a new SP features as explained in CR 6724613. SymptomsAfter ILOM 2.0.2.5 has been installed, C2 and C3 device names are no longer used by the SP and will become avaliable for disk device names causing a shift in several disk device names.Examples: Output from the hd utility on a system with ILOM 2.0.2.1 or earlier Root CauseSee Contributing Factors and Symptoms sections above.Corrective ActionWorkaround:No workaround available - see Resolution section below. Resolution: Map both devices (CD-ROM and Floppy) in the JavaRConsole before reinstalling if PRE ILOM 2.0.2.5 disk drive mapping is desired. For additional information on how the disks can differ, refer to: Sun Fire X4500 Server Installation Guide (Sun P/N 819-4358-11) Section Titled: "Important Solaris OS Installation and Bootable Hard Disk Drive Guidelines" For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: For Sun Authorized Service Providers go to: In addition to the above you may email: Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Responsible Manager: [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group SSG WGS Internal Sun Alert & FAB Admin Info 17-Sep-2008: Completed draft and sent to Extended Review. 18-Sep-2008: Chris Johnson stated he is not the RE. Put FAB onhold awtg response from submitter. 19-Sep-2008: chgd Responsible Engineer and Manager per Submitter. Sent to Publish. 07-Dec-2009: Corrected Product Name to swoRDFish inconsistency. Attachments This solution has no attachment |
||||||||||||
|