Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1001305.1
Update Date:2010-09-01
Keywords:

Solution Type  FAB (standard) Sure

Solution  1001305.1 :   Sun Ultra 40 Workstations with Acbel power supplies may display error at boot time.  


Related Items
  • Sun Ultra 40 Workstation
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
201766


Product
Sun Ultra 40 Workstation

Bug Id
<SUNBUG: 6471932>

Part
  • Part No: 300-1800-xx
  • Part Description: AcBel API4FS35-470G 1000 Watt Power Supply

Impact

Some Sun Ultra 40 Workstations with AcBel power supplies may display an error message at boot up and the boot process will hang.  Pressing the F1 key on the keyboard will allow booting to complete.


Contributing Factors

This could affect Sun Ultra 40 Workstations having an AcBel power supply unit.  Not all AcBel units are impacted, but the affected date code range has not been determined yet.  Systems with Delta power supplies are not affected.  Sun Ultra 25 and Sun Ultra 45 systems use the same PSU but are not affected because they do not verify the PSU checksum during POST.


Symptoms

When this issue occurs the following message will display on the console.

   ERROR
   0284:PS FRU checksum failed!
   ERROR 0285 FRU EEPROM access disabled

The boot sequence will stop at this point.


Root Cause

AcBel power supplies were installed with incorrect CRC code.  This causes the error message and hang during BIOS POST.


Workaround

If this error is encountered, the user should press the F1 key on the keyboard and booting will continue normally.


Resolution

The following link will get you to an .ISO image to create a bootable CD that can be used to upgrade the power supply FRU. This is only for use to update the power supply FRU until the official 1.5 tools and drivers is released and this image should not be used to update BIOS/drivers etc on a shipping platform;

/net/ctforh.east/pub/testbios/sirius/psfru-1.4/

Once you have the cd image, insert the CD into the U40 drive. Make sure the BIOS has the CD-ROM listed as a bootable device.  At the menu select number 4 ( Exit to Dos).

Change directory to PSFRU.

Read the README file for information. It is advisable to run the utility with the -p option first to verify the checksum value needs to be changed. Do not run psfru -f without verifying it is needed.

How to run:  There are 4 switches which are:

-v Verbose Output (optional)

-p Print output (nice to use - print all FRU fields)

-f Recalculate and re-write the power supply FRU PROM checksum

-h Help (display this info)

Output on a bad power supply looks similar to this:

C:\psfru -p

PSFRU v1.0

SM Bus Base Address: 7040

Spec Part Number 885-0468-01

Sun Part Number 3001800

Time Stamp Tue Oct 11 14:34:56 2005

Serial Number 123456

Vendor ID 05ab (Acbel)

Checksum32: 429662e5. Checksum from FRU PROM: 42969de5

**** PSFRU CHECKSUM ERROR. Use -f switch to re-write correct checksum

After re-running the program with -f, good output looks like this:

C:\psfru -p

PSFRU v1.0

SM Bus Base Address: 7040

Spec Part Number 885-0468-01

Sun Part Number 3001800

Time Stamp Tue Oct 11 14:34:56 2005

Serial Number 123456

Vendor ID 05ab (Acbel)

Checksum32: 429662e5. Checksum from FRU PROM: 429662e5

PSFRU CHECKSUM is Ok.


Modification History
Date: 11-OCT-2006
  • updated Resolution section with psfru-1.4 .ISO image availability as resolution.

Date: 19-OCT-2006
  • corrected pathname in Resolution section by adding domain of .east.


Previously Published As
102626
Internal Comments


None.


Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
KE Authors

Internal Services Knowledge Engineer
[email protected], [email protected]

Internal Escalation ID
1-19665897

Internal Kasp FAB Legacy ID
102626

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date: 2006-09-27
Avoidance: Upgrade, Workaround
Responsible Manager: [email protected]
Original Admin Info: WF - Updated Resolution section