Solution Type FAB (standard) Sure Solution 1001304.1 : A Limited Number of T1000/T1000+ Systems and T2000/T2000+ Shipped From Factory With the Incorrect OS Version
PreviouslyPublishedAs 201764 Product Sun Fire T2000 Server Sun Fire T1000 Server Impact A limited number of T1000 systems were erroneously shipped with Solaris 10 Update 2 (6/06) instead of Solaris 10 Update 1 (1/06), and similarly, T1000+ systems were shipped with Solaris 10 Update 1 (S10U1) instead of Solaris 10 Update 2 (S10U2). Also, a limited number of T2000 and T2000+ systems were erroneously shipped with Solaris 10 Update 2 instead of S10 Update 1 as stated in the product documentation. Contributing Factors This issue occurs on the following platforms:
In the case of the T1000+, S10U1 is not the supported OS version. For the other systems, this will not cause any operational issues, but the systems may be different from the customer's standard configuration. Affected Customer Lists have been provided and can be accessed via the below (Internal Only) URLs; T1000 Serial Number List: http://sdpsweb.central/FIN_FCO/FAB/102632/SPE/T1000_serial_number_list.txt T2000 Serial Number List: http://sdpsweb.central/FIN_FCO/FAB/102632/SPE/T2000_serial_number_list.txt Symptoms For T1000 (with S10U2): the only issue is that the 'uname' command will display another OS version, but this has no direct effect on normal operation. For T1000+ (with S10U1): the system will get the following message when booting: /pci@7c0/pci@0/pci@8/scsi@2 (mpt0): mpt0: unknown event 16 received This message is due to the fact that the LSI 1.10.00IR firmware requires patch 119850-14 (mpt/raidctl) to be installed on the system, but S10U1 comes with 119850-08. If patch 119850-14 or later is installed, the system will no longer report these messages, however, this is not the recommended fix. See below. For T2000/T2000+ (with S10U2): no direct impact. Root Cause An incorrect flash archive was used for the OS install process during manufacturing. A fix was implemented in manufacturing on Aug. 30, 2006. Workaround
Resolution For the T1000 with S10U2 installed:
For the T1000+ with S10U1 installed:
Note: It is not recommended to only install the mpt/raidctl patch (119850-14 or later) and other required patches for S10U1, because the minimum supported version for T1000+ is S10U2 (6/06), as documented in the T1000 product notes: http://www.sun.com/products-n-solutions/hardware/docs/html/819-3246-13/ For the T2000/T2000+ with S10U2 (6/06) installed:
http://www.sun.com/products-n-solutions/hardware/docs/html/819-2544-18/ Modification History Date: 27-SEP-2006
Date: 06-OCT-2006
Date: 30-OCT-2006
Previously Published As 102632 Internal Comments For T1000 see: http://www.sun.com/products-n-solutions/hardware/docs/html/819-3246-13/
For T2000 see: http://www.sun.com/products-n-solutions/hardware/docs/html/819-2544-18/ Internal Contributor/submitter [email protected] Internal Eng Business Unit Group SSG WGS (Workgroup Systems) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected], [email protected] Internal Kasp FAB Legacy ID 102632 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2006-09-26 Avoidance: Upgrade Responsible Manager: [email protected] Original Admin Info: null Product_uuid 096f8bf9-8ede-11da-8387-080020a9ed93|Sun Fire T2000 Server 79ad78b9-961d-11d9-9adf-080020a9ed93|Sun Fire T1000 Server Attachments This solution has no attachment |
||||||||||||
|