Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1001288.1 : Sun StorEdge 9970 and 9980 DKA or FSW replacement may result in HDD Port blockade.
PreviouslyPublishedAs 201748 Product Sun StorageTek 9970 System Sun StorageTek 9980 System Xoption
Impact Replacing a DKA or FSW may result in HDD Port blockades when I/O activity is started during Path INLINE diagnostic A2 or A8 routine. Verify HDD Port Status is NORMAL on the Maintenance status display window of the SVP following a DKA or FSW replacement. Resolution If HDD Port blockades occur, re-attempt DKA or FSW replacement. Microcode DKCMAIN 21-13-01-00/00 and later has been modified to fix the issue. Modification History Date: 21-MAR-2007
Previously Published As 101724 Internal Comments Abbreviations used in this FIN. . DKA: Disk Unit Adapter . FSW: Fibre SWitch . HDD: Hard Disk Drive . I/O: Input/Output . SVP: SerVice Processor Related Information
Internal Eng Business Unit Group KE Authors Internal Services Knowledge Engineer Joe Davis (as of 3/21/07) Internal Kasp FAB Legacy ID 101724, I1205-1 (FIN) Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2005-05-27 Avoidance: Upgrade Responsible Manager: null Original Admin Info: WF - changed Product from KASP to SE9970 and SE9980. - Joe 3/21/07 Product_uuid 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System c2428fbe-8ab7-41d0-8b6e-ab489823c9d4|Sun StorageTek 9980 System Attachments This solution has no attachment |
||||||||||||
|