Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1001170.1 : Installing FRU 540-5768-05 With StorEdge 6920 (System 1) Version 2.0.4 or Earlier Will Create Booting Issues.
PreviouslyPublishedAs 201564 Product Sun StorageTek 6920 System Bug Id <SUNBUG: 6230093> Part
Impact All Sun StorEdge 6920 Systems with Storage Resource Card (SRC2), FRU Number 540-5768-05, fail to boot with systems running version 2.0.4 or earlier. Note: Only rev -05 cards are affected. Symptoms
Root Cause The Galileo Universal Asynchronous Receiver Transmitter (UART) code is very CPU intensive due to the fact that input interrupts do not work on the RevB Galileo, causing failure to boot. Workaround If a SRC2 card (FRU 540-5768-05) is installed, the system must be upgraded to version 2.0.5 or higher (this can includes 3.0.x versions). Previously Published As 102359 Internal Contributor/submitter [email protected] Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Kasp FAB Legacy ID 102359 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: Avoidance: Firmware Responsible Manager: null Original Admin Info: null Internal SA-FAB Eng Submission Installing FRU 540-5768-05 with StorEdge 6920 (System 1) version 2.0.4 or earlier will create incompatibility issues. SRC2 card will fail to boot to the operating level. Product_uuid 67794720-356d-11d7-8ef2-ce2ac2bc9136|Sun StorageTek 6920 System Attachments This solution has no attachment |
||||||||||||
|