Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1001125.1 : SATA drive support for 25xx Array requires 06.70.00.1 or later Controller Firmware.
PreviouslyPublishedAs 201507 Product Sun StorageTek 2530 Array Sun StorageTek 2540 Array Bug Id <SUNBUG: 6498807> Impact Common Array Manager (CAM) Versions 5.1.3, and 6.0 both release with Controller firmware revision 06.17.52.10. For SATA drive feature support, it is required that Controller firmware 06.70.00.1 or later be installed on 25x0 arrays. Depending on host platform, this firmware can be obtained via resolved patches listed below and currently available. Please ensure patch firmware is applied offline during a maintenance window when there is no I/O activity to the array. Contributing Factors Sun StorageTek 25x0 Arrays with controller firmware earlier than 06.70.00.1 is impacted by this issue. Basic SATA drive feature support is not included in versions earlier than 06.70.00.1. Dysfunction of the SATA drives may lead to major issues and data integrity problems (see Symptoms section below). Symptoms There are several bugs that are included in the new controller firmware. See the patch README file for a specific bug list. Root Cause There are several bugs that are included in the new controller firmware. See the patch README file for a specific bug list. Workaround
Resolution Install the correct CAM patch and follow instructions in the README file for the correct installation procedures as follows: For CAM 5.1.3 the following patches are available: 127486-01 Solaris 127487-02 Windows 127488-01 Linux For CAM 6.0 the following patches are available: 128269-01 Solaris 128270-01 Windows 128271-01 Linux These patches include: Controller: 06.70.00.11 NVSRAM: 670843 DISK: HDS7250SASUN500G.AJ0A IOM: 183 The correct revision of firmware will be packed with CAM 6.0.1 (or later) which is planned to include the new version from download site in late November or early December 2007. Important Note: Ensure patch firmware is applied offline during a maintenance window when there is no I/O activity to the array as indicated in the 2500 Release Notes (820-3411-10 pages 10-11). Modification History Date: 19-NOV-2007
Date: 12-DEC-2007
Previously Published As 103093 Internal Comments Related Information
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Resolution Patches 127486-01, 127487-02, 127488-01, 128269-01, 128270-01, 128271-01 Internal Kasp FAB Legacy ID 103093 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2007-10-02 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: WF - rcvd submissiion. - Joe 9/27/07 WF - completed draft and sent to Ext Rvw. - Joe 9/28/07 WF - FAB put onhold awtg Patch availability. - Joe 9/28/07 WF - chgd Resolution to allow FAB publication prior to patch availability. - Joe 9/28/07 WF - changed to Preliminary and will be updated when Pete Babich informs us when all three patches are available. Sending to Publish as there was no feedback during Ext Rvw. - Joe 10/02/07 WF - chgd from Premliminary to Resolved as all 6 patches are now available. - Joe 11/19/07 WF - added statement in Impact section and Note in Resolution section to apply patch offline per request from Bryan Curry via Sue Copeland. - Joe 12/12/07 Product_uuid 79213559-6949-11db-a023-080020a9ed93|Sun StorageTek 2530 Array addb4e49-910b-11db-9e93-080020a9ed93|Sun StorageTek 2540 Array Attachments This solution has no attachment |
||||||||||||
|