Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000815.1 : Sun Ultra 20 Workstation with 4 x 1GB of memory will not power on.
PreviouslyPublishedAs 201094 Product Sun Ultra 20 Workstation Part
Impact System will not power on. Contributing Factors Any Ultra 20 with 4 x 1GB of memory and a 300-1794-02 (or below) power supply is exposed. There is no Sun shipped configuration for the Ultra 20 with 4 x 1GB of memory. The 4 x 1GB memory configuration can only be obtained by upgrading the system via a memory xoption. Symptoms Sun Ultra 20 Workstations loaded with 4 Gigabites of memory and containing the -01 or -02 power supply can drive the power supply to the edge of its performance limits resulting in a system that will not power on. In the Bios it is possible to configure a system to either power down in the event of a power issue or reboot. If a system is set to power down and this issue occurs, it will simply power down and, upon manual re-power, it will power itself down again. If a system is set to automatically reboot and this issue occurs the system will enter a continuous cycle of automatically powering down and trying to reboot only to power down again. Corrective action has been made available in Manufacturing via ECO WO_32375 cut-over as of January 30, 2006, and in Services via GSAP 3309 issued on February 7,2006. Root Cause The validated root cause of this problem has been determined to be specific components within the power supply itself. Two capacitors and a diode have been changed to increase the power margins. Accordingly, the power supply has been dash rolled to -03 to reflect the upgraded version that has the margins to successfully support a 4 x 1GB memory configuration. The validated corrective action to resolve this issue in the field is to replace the power supply with an updated power supply should a system loaded with 4 x 1GB of memory fail to power on. Workaround
Resolution Replacement Time Estimate: 30 minutes (per PSU) Hot Swappable: No
Previously Published As 102544 Internal Comments Note: This Hardware FAB went through planning under FCO# A0268-1. Hardware Remediation Details This FCO will have a time zone phased release based on material readiness as follows:
The above dates represent when each time zone has determined that it will be materially ready to support this FCO. All dates are estimates. Please check with your Logistics Representative or TZ / Country / Area FCO Manager for more information with regard to material availability and the parts ordering process for this FCO. Related Information
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NSG (Network Systems Group) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Kasp FAB Legacy ID 102544 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2006-07-31 Avoidance: Hardware Replacement Responsible Manager: [email protected] Original Admin Info: WF - joe released on 7-31-2006. WF - karen and joe created 7-27-2006. Joe working as part of Tiger Team see sunwebcollab folder. Waiting for closure on purge. Internal SA-FAB Eng Submission ------------------------------------------------------------------------ *** Sun Confidential: Internal Use and Authorized VARs Only *** ________________________________________________________________________ This message including any attachments is confidential information of Sun Microsystems, Inc. Disclosure, copying or distribution is prohibited without permission of Sun. If you are not the intended recipient, please reply to the sender and then delete this message. ________________________________________________________________________ FIELD CHANGE ORDER (For Authorized Distribution by Sun Services) FCO #: A0268-1 DATE: July 13, 2006 SYNOPSIS: Sun Ultra 20 Workstation with 4 x 1GB of memory will not power on. Sun Alert: No TOP FIN/FCO REPORT: No PRODUCT REFERENCE: Ultra 20 Workstation PRODUCT CATEGORY: Server / Memory - Server / Power PRODUCT AFFECTED: Systems Affected: ------- -------- Mkt_ID Platform Model Description Serial Number ------ -------- ----- ----------- ------------- - A63 - Sun Ultra 20 Workstation - X-Options Affected --------- ------- Mkt_ID Platform Model Description ------ -------- ----- ----------- x8006A - - 2GB (2 * 1GB DDR400/PC3200 ECC DIMM) Option AFFECTED PARTS: Part Number Description ----------- ----------- 300-1794-02 (or below) 400 Watt Power Supply REFERENCES: ECO: WO_32375 GSAP: 3309 ISSUE DESCRIPTION: Sun Ultra 20 Workstations loaded with 4 Gigabites of memory and containing the -01 or -02 power supply can drive the power supply to the edge of its performance limits resulting in a system that will not power on. Any Ultra 20 with 4 x 1GB of memory and a 300-1794-02 (or below) power supply is exposed. There is no Sun shipped configuration for the Ultra 20 with 4 x 1GB of memory. The 4 x 1GB memory configuration can only be obtained by updgrading the system via a memory xoption. In the Bios it is possible to configure a system to either power down in the event of a power issue or reboot. If a system is set to power down and this issue occurs, it will simply power down and, upon manual re-power, it will power itself down again. If a system is set to automatically reboot and this issue occurs the system will enter a continuous cycle of automatically powering down and trying to reboot only to power down again. The validated root cause of this problem has been determined to be specific components within the power supply itself. Two capacitors and a diode have been changed to increase the power margins. Accordingly, the power supply has been dash rolled to -03 to reflect the upgraded version that has the margins to successfully support a 4 x 1GB memory configuration. The validated corrective action to resolve this issue in the field is to replace the power supply with an updated power supply should a system loaded with 4 x 1GB of memory fail to power on. Corrective action has been made available in Manufacturing via ECO WO_32375 cut-over as of January 30, 2006, and in Services via GSAP 3309 issued on February 7,2006. IMPLEMENTATION: --- | | MANDATORY (Fully Proactive) --- --- | | CONTROLLED PROACTIVE (per Sun Geo Plan) --- --- | X | REACTIVE (Upon Failure) --- IMPLEMENTATION TARGET COMPLETION DATE: Not Applicable REPLACEMENT TIME ESTIMATE: 30 minutes (per PSU) SPECIAL CONSIDERATIONS: This FCO will have a time zone phased release based on material readiness as follows: Readiness Date -------------- US/Canada Jul/27/06 Ltn America Aug/07/06 EMEA Jul/31/06 APAC Aug/09/06 ANZO Aug/09/06 Japan Aug/09/06 The above dates represent when each time zone has determined that it will be materially ready to support this FCO. All dates are estimates. Please check with your Logistics Representative or TZ / Country / Area FCO Manager for more information with regard to material availability and the parts ordering process for this FCO. CORRECTIVE ACTION: Hot Swappable: No Upon failure only replace as follows: Replace with ------- ---- 300-1794-02 (or below) 300-1794-03 (or above) or 300-1950-01 (or above) COMMENTS: CHANGE HISTORY: Jul/xx/06 - Initial release. ________________________________________________________________________ For questions on this document, please email: [email protected] The FCO home page is available at: http://tns.central/fco For more information on how to submit a FCO, go to: http://pronto.central/fco.html To access the Service Partner Exchange, use: https://spe.sun.com NOTE: FCO Tracking Instructions for Radiance/SPWeb: -------------------------------------------------- If a Radiance case involves the application of an FCO to solve a customer issue, please complete the following steps in Radiance/SPWeb prior to closing the case: o Select "Field Change Order" in the REFERENCE TYPE field. o Enter FCO ID number in the REFERENCE ID field. For example; A0257-1. If possible, include additional details in the REFERENCE SUMMARY field (ie. Upgrade complete, customer declined, etc.) Implementation Notes -------------------- In case of "Mandatory" FCOs, Sun Services will attempt to contact all known customers to recommend proactive implementation. For "Controlled Proactive" FCOs, Sun Services mission critical support teams will initiate proactive implementation efforts for their respective accounts, as required. For "Upon Failure" FCOs, Sun Services and partners will implement the necessary corrective actions as the need arises. The CIC process must be used for proactive hardware replacement requests when an FCO is classified as "Upon Failure". Billing Information ------------------- Warranty: Sun will provide parts at no charge under Warranty Service. On-Site Labor Rates are based on specified Warranty deliverables for the affected product. Contract: Sun will provide parts at no charge. On-Site Labor Rates are based on the type of service contract. Non Contract: Sun will provide parts at no charge. Installation by Sun is available based on the On-Site Labor Rates defined in the Price List. Product_uuid 372415be-961d-11d9-9adf-080020a9ed93|Sun Ultra 20 Workstation Attachments This solution has no attachment |
||||||||||||
|