Solution Type  FAB (standard) Sure

Solution  1000682.1 :   Array performance degradation as a result of the cache changing to write-through.  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3310 Array
  •  
  • Sun Storage 3511 SATA Array
  •  
  • Sun Storage 3320 SCSI Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Controlled Proactive
  •  

PreviouslyPublishedAs
200894


Product
Sun StorageTek 3310 SCSI Array
Sun StorageTek 3510 FC Array
Sun StorageTek 3320 SCSI Array
Sun StorageTek 3511 SATA Array

Bug Id
<SUNBUG: 6327514>, <SUNBUG: 6256792>


Impact

Firmware 4.1x introduced a new functionality to decide when the cache changes to write-through.  This is the auto-write-through-trigger. One of the triggers is battery-backup-failure which, when enabled, will change the cache to write-though should a battery fail.

However, this trigger does not distinguish between a battery failure and a re-charge cycle.  As a result, performance of the array degrades to add to the performance hit already caused by the 4.1x firmware.


Symptoms

Battery re-charging messages indicating the re-charging cycle, followed by the cache changing to write-through.  Consequently a drop in i/o performance.

<Tue Jan 24 02:06:43 2006> Controller BBU is Charging !
<Tue Jan 24 02:06:44 2006> Force Controller Write-Through on Trigger Cause
<Tue Jan 24 05:55:12 2006> NOTICE: Controller BBU Fully Charged !
<Tue Jan 24 05:55:12 2006> Controller Default Write Policy Restore

Root Cause

The controller firmware 4.1x is unable to distinguish between a battery failure and a battery re-charging event.


Workaround

Patch Information per Array:

  • Patch 113723-15 is for SE3510 FC Array
  • Patch 113724-09 is for SE3511 SATA Array
  • Patch 113722-15 is for SE3310 SCSI Array
  • Patch 113730-01 is for SE3320 SCSI Array

Resolution

 


Previously Published As
102222
Internal Comments


 


Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
KE Authors

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Escalation ID
1-12760796

Internal Resolution Patches
113723-15, 113724-09, 113722-15, 113730-01

Internal Kasp FAB Legacy ID
102222

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date:
Avoidance: Firmware
Responsible Manager: null
Original Admin Info: null

Internal SA-FAB Eng Submission
Bug 6327514 causes array performance degradation as a result of the cache changing to write-through.

Product_uuid
3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array
58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array
95288bce-56d3-11d8-9e3a-080020a9ed93|Sun StorageTek 3320 SCSI Array
9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback