Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1000669.1
Update Date:2011-02-10
Keywords:

Solution Type  FAB (standard) Sure

Solution  1000669.1 :   Sun Fire V20z/V40z - If the Service Processor (SP) fails to boot, 'boot mode' may have been altered and needs setting to the default value.  


Related Items
  • Sun Fire V20z Server
  •  
  • Sun Fire V40z Server
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200881


Product
Sun Fire V20z Server
Sun Fire V40z Server


Impact
This FIN is to inform the field of an issue on Sun Fire V20z and
V40z systems that have an SP boot mode issue often exhibited by
blank front LCD panel.  As a result of this issue you will be
unable to access the Service Processor or configure SP via
front panel. 

Symptoms
Front LCD panel will be blank or you may experience an issue
connecting to the SP at boot mode has not completed.
To identify this issue, you will observe that the front LCD panel
is back lit with a light, but no characters.  Additionally, you
will not be able to configure any of the normal setup features
from the front panel.


Root Cause
The vendor supplied root cause is that 'Boot mode' has been altered
and this needs to be set to defaults.
PTS has been informed that a high percentage of systems have seen
this issue in the field.


Resolution
If the field encounters this symptom, please adhere to the following step-by-
step procedure and perform accordingly.
1. Attach a PC to the Serial Port. A. Jumper J19 to set the Service Processor output to the Serial Port. - OR - B. Logging in to the Service Processor with a Manager ( you will need to create a Service account) or Service account. In either case, the field must perform the following steps. 2. Remove AC power. 3. Jumper TH84 - located under the power supply at the end of the 66-MHz PCIx slot. a. On Sun Fire V20Z, the "clear CMOS" jumper J110 can be used, if necessary. b. On Sun Fire V40Z, the "clear CMOS" jumper J125 can be used, if necessary.
Using the Serial Port --------------------- 4. Attach a PC to the Serial Port. 5. Apply AC Power. NOTE: The space bar needs to be depressed within three seconds Serial Port will show. Hit any Key to Stop Autoboot = 0. 6. Depress the space bar for three seconds. 7. At the prompt => type "saveenv". 8. Remove AC power. 9. Remove Jumper TH84. 10.The Service Processor will now work properly.

Using the Service Processor ---------------------------
See the Sun Fire v40z /v20z Set-Up Guide for instructions on how to set up the Service Processor
1. Log in to the Service Processor using a "service" account. 2. At the prompt $ type sp set root on. 3. your password: <service password>. 4. New root password: <make something up>. 5. Confirm root password: <same as above>. 6. At the prompt $ type su -. 7. password: <this is the new made up root password>. 8. At the prompt # type setenv uboot 0. 9. Remove AC power. 10. Remove Jumper TH84. 11. The Service Processor will now work properly.

Modification History
Date: 01-FEB-2006
  • Added jumper settings for the SF V40Z.


Previously Published As
100705
Internal Comments






The RR/GA Dates for V20z and V40z products.

v20z RR Date: 3/22/2004 (Man. Fact. Part # 380-0979)

v20z GA Date: 4/22/2004 (Man. Fact. Part # 380-0979)

v40z RR Date: 6/28/2004 (Man. fact. Part # 380-1010)

v40z GA Date: 7/28/2004 (Man. fact. Part # 380-1010)


============================================================================



Internal Eng Business Unit Group
KE Authors

Internal Services Knowledge Engineer
[email protected]

Internal Kasp FAB Legacy ID
100705, I1185-1 (FIN)

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date:
Avoidance: Patch
Responsible Manager: null
Original Admin Info: null

Internal SA-FAB Eng Submission
Sun Fire V20z/V40z - If the Service Processor (SP) fails to boot, 'boot mode' may have been altered and needs setting to the default value.

Product_uuid
1acc55b3-4b82-11d8-99fc-080020a9ed93|Sun Fire V20z Server
4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback