Solution Type  FAB (standard) Sure

Solution  1000234.1 :   Solaris 10 I/O issue on Sun Fire 12K/15K/20K/25K domains.  


Related Items
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 15K Server
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200309


Product
Sun Fire 12K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire E25K Server

Bug Id
<SUNBUG: 6243241>


Impact

A Solaris 10 domain running on a Sun Fire 12K/15K/20K/25K platform may lose access to PCI adapters on the 7th configured I/O board and all I/O boards beyond.  For example, a domain configured with boards SB2, SB3, IO2, IO4, IO5, IO6, IO8, IO9, IO10 and IO12 will lose access to PCI adapters on IO10 and IO12.  Using Dynamic Reconfiguration (DR) to bring a 7th I/O board into a domain will also manifest the bug.


Symptoms

During domain boot, messages such as the following will be displayed on the console:

   Apr 9 04:12:23 2005 WARNING: (7):sbbc_attach failed to map sbbc_reg
   Apr 9 04:12:23 2005 WARNING: (8):sbbc_attach failed to map sbbc_reg
   Apr 9 04:12:23 2005 WARNING: (9):sbbc_attach failed to map sbbc_reg

If the issue is experienced during a DR operation, the SBBC register mapping failure will be logged to the domain console and the /var/adm/messages file.


Root Cause

The Solaris 10 kernel's PIOMAPSIZE is insufficiently large to satisfy the register mapping requirements of the SBBC driver.  PCI adapters on I/O boards 7 and higher are unable to be mapped into the kernel and become inaccessible.  See bug 6243241 for full details.


Workaround

Resolution

Install Solaris 10 patch 118822-11 (or later) on any affected domain.


Modification History
Date: 12-AUG-2005
  • Changed document from PFIN to FIN because resolution patch is now available.


Previously Published As
101866
Internal Comments


None.


Internal Eng Business Unit Group
KE Authors

Internal Resolution Patches
118822-11

Internal Kasp FAB Legacy ID
101866

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date:
Avoidance: Patch
Responsible Manager: null
Original Admin Info: null

Product_uuid
077fd4c5-df8f-4320-ad69-7d01603a674d|Sun Fire 12K Server
1404a2d3-059a-11d8-84cb-080020a9ed93|Sun Fire E20K Server
29e4659c-0a18-11d6-9fa1-e67bbc033df8|Sun Fire 15K Server
d842dd03-059b-11d8-84cb-080020a9ed93|Sun Fire E25K Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.