Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1000078.1
Update Date:2010-07-06
Keywords:

Solution Type  FAB (standard) Sure

Solution  1000078.1 :   System door interferes with Tape Drive operation.  


Related Items
  • Sun Netra 1280 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200094


Product
Sun Fire E2900 Server
Sun Fire V1280 Server
Netra 1280 Server

Date of Resolved Release
01-MAY-2006

Part
  • Part No: 560-2744
  • Part Description: Right Door and Hinge FRU, E2900
Part
  • Part No: 560-2725
  • Part Description: Right Door and Hinge FRU, V1280/Netra 1280
Part
  • Part No: 380-1328
  • Part Description: DAT 72 Internal Tape Drive, 3.5 inch/68 pin SCSI, RoHS:Y
Part
  • Part No: 380-1005
  • Part Description: 36-72GB 4 mm DAT 72 3.5-inch Tape Drive
Xoption
  • Xoption Number: SG-XTAPDAT72-3F-2
  • Xoption Description: DAT 72 Internal Tape Drive, 3.5 inch/68 pin SCSI, RoHS:Y
Xoption
  • Xoption Number: SG-XTAPDAT72-3F68
  • Xoption Description: 36-72GB 4 mm DAT 72 3.5-inch Tape Drive

Impact

The original issue was alignment of E2900/V1280/Netra 1280 door eject button (on Right Hand door) with (non-RoHS) Dat72 option. The tape could not be ejected properly, or could be ejected accidentally.

When the RoHS DAT72 option was released, there then became some misalignment between LED holes in doors and the LEDs of the DAT72 drive, rendering the LED's unreadable, and the tape could still not be ejected properly.


Contributing Factors

Netra 1280, Sun Fire E2900 and Sun Fire V1280 when the DAT72 tape drive is present and a Non-RoHS right hand door is closed.


Symptoms

Multiple messages, similar to the following, may be observed when this issue results in the tape drive attempting to eject a tape when no tape is present.

02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot open /dev/rmt/0l:
I/O error." Probable_Cause(s): <No tape media in drive.> Recommended_Action(s): <Load tape media
and retry test.> (run_on_error message 1)

 


Root Cause

The right hand doors listed under Affected Parts section above, and the DAT72 tape drive were not properly aligned / positioned resulting in this issue.

The new right hand door has the LED holes and eject button removed to eliminate the alignment issue.  These changes were cut into Manufacturing in May of 2006 via ECO# WO_29351.


Resolution

Replacement Time Estimate: 30 minutes

Hot Swappable: Yes

Upon failure or customer request replace Right Door and Hinge as follows:

Sun Fire V1280 and Netra 1280 

  • replace 560-2725 with 560-2848

Sun Fire E2900

  • replace 560-2744 with 540-7019

 


Previously Published As
102842
Internal Comments


This asset was fully evaluated as an FCO by Sun Quality and found not to meet criteria due to the small exposure and potential for experiencing this issue.


Related Information
  • ECO: WO_29351

Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
KE Authors

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Kasp FAB Legacy ID
102842

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date: 2007-03-13
Avoidance: Hardware
Responsible Manager: [email protected]
Original Admin Info: WF - started initial draft. - Joe 3/09/07
WF - made minor mods per Responsible Eng. - Joe 3/13/07

Internal SA-FAB Eng Submission
Field Action Bulletin (FAB) BLANK Submittal Template


For Preliminary, Non-Hardware and Hardware FABs --


After following instructions for drafting a Field Action Bulletin,
send this ASCII Text filled-in template to:


[email protected]


The email Subject line should be similar to the following:


Draft Field Action Bulletin / Synopsis ...


---------------------------------------------------------------


Synopsis:


Avoidance:

[ ] Binary

[ ] T-Patch

[ ] Patch

[ ] Firmware

[X] Hardware

[ ] Upgrade

[ ] Workaround

[ ] Reconfiguration

[ ] Service Procedure

[ ] None

[ ] Hardware Replacement (Must follow SMI FCO Process) *



* Note:Please follow the below link for details on how

to submit an FCO;



http://sunwebcollab.central.sun.com/gm/folder-1.11.811470



Implementation:



[X] Reactive (Upon Failure)

[ ] Controlled Proactive (H/W FABs require Customer List and

Customer Letter)

[ ] Mandatory (Requires Customer List and Customer Letter)





Product: (Mktg Part Number / Description)

A40-WSPF4-8GGB1

A40-WSPF8-16GGB

A40-WSPF12-24GG

A40-WSPF12-96GG

N40-WSPF4-8GGB1

N40-WSPF8-16GGB

N40-WSPF12-24GG

N40-WSPF12-96GG

A40-4P1200-8GB

A40-4P1200-16GB

A40-4P1200-32GB

A40-8P1200-16GB

A40-12P1200-24G

N40-4P1200-8GB

N40-4P1200-16GB

N40-4P1200-32GB

N40-8P1200-16GB

N40-12P1200-24G

E29-4P16GB-1050

E29-8P32GB-1050

E29-12P48GB-1050

E29-4P32GB-1050

E29-8P64GB-1050

E29-12P96GB-1050

E29-4P16GB-1200

E29-8P32GB-1200

E29-12P48GB-1200

E29-4P32GB-1200

E29-8P64GB-1200

E29-12P96GB-1200

E29-4P16GB-1350

E29-4P32GB-1350

E29-4P64GB-1350

E29-8P32GB-1350

E29-8P64GB-1350

E29-8P128GB-1350

E29-12P48GB-1350

E29-12P96GB-1350

E29-12P192GB-1350

E2900-BASE

E2900-BASE2

SYS2900A-4-1500

SYS2900B-4-1500





Affected X-Options: (Xoption Part Number / Description)



SG-XTAPDAT72-3F-2 / DAT 72 Internal Tape Drive, 3.5 inch/68 pin SCSI, RoHS:Y

SG-XTAPDAT72-3F68 / 36-72GB 4 mm DAT 72 3.5-inch Tape Drive



Affected Parts: (FRU/CRU Part Number / Description)

380-1328 / DAT 72 Internal Tape Drive, 3.5 inch/68 pin SCSI, RoHS:Y

380-1005 / 36-72GB 4 mm DAT 72 3.5-inch Tape Drive

560-2744 / Right Door and Hinge FRU

560-2725 / Right Door and Hinge FRU





Issue Description:



Impact



[This should explain the impact to the running system in

general and the impact to the affected component in particular;

in terms of outage, downtime, loss of availability, loss

of data, etc. State the actual impact, for example,

the issue causes a system panic, reset, hang etc. If this is

a serviceability issue, state how it affects the ability to

service or maintain the product.]



1) Original problem was alignment of E2900/V1280/Netra 1280 door eject

button (on Right Hand door) with (non-RoHS) Dat72 option. The tape

could not be ejected properly (or could be ejected accidentally)



2) When RoHS DAT72 option was released there then became some

misalignment between LED holes in doors and the LEDs of the DAT72 drive

rendering the LED's unreadable (and the tape could still not be ejected

properly).







Contributing Factors



[List anything, such as specific operating environments and/or

configurations that may contribute to the issue.]



Issue can happen when the DAT72 tape drive is present and a Non-RoHS

right hand door is closed.



Symptoms



[Provide exact error messages and where and when the error

messages are likely to occur.]



Errors similar to the following may be observed when this issues results in

the tape drive attempting to eject a tape when no tape is present.



02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot

open /dev/rmt/0l: I/O error." Probable_Cause(s): Recom

mended_Action(s): (run_on_error message 1)

02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot

open /dev/rmt/0l: I/O error." Probable_Cause(s): Recom

mended_Action(s): (run_on_error message 1)

02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot

open /dev/rmt/0l: I/O error." Probable_Cause(s): Recom

mended_Action(s): (run_on_error message 1)

02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot

open /dev/rmt/0l: I/O error." Probable_Cause(s): Recom

mended_Action(s): (run_on_error message 1)

02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot

open /dev/rmt/0l: I/O error." Probable_Cause(s): Recom

mended_Action(s): (run_on_error message 1)

02/14/07 11:30:50 str8-a SunVTS6.3ps1: VTSID 6002 tapetest.ERROR tape0: "Cannot

open /dev/rmt/0l: I/O error." Probable_Cause(s): Recom

mended_Action(s): (run_on_error message 1)



Root Cause



[This is ultimate cause of the issue and can be provided in

engineering/technical terms.]



The right hand doors listed under parts effected and the DAT72 tape drive

were not properly aligned / positioned resulting in the issue.



[Explain how and when the issue was resolved by manufacturing,

engineering or by the vendor.]



New Right hand door provides proper alignment between the LED and holes in the door

as well as the eject button. These changes were cut in in May of 2006



Corrective Action:



Supported Workaround (if available)



N/A



Final Resolution



[Provide recommended action for Sun Field personnel to

follow in order to implement this fix in the field.]



Replace right hand door as follows:



V1280/Netra 1280 560-2848 / Right Door & Hinge Kit, RoHS:Y

E2900 540-7019 / Right Door and Hinge, RoHS:Y



[A detailed step-by-step procedure for implementing the fix,

or high level instructions together with pointers to specific

documentation pages.]



[List all relevant product manuals, documentation and URL's which

will help to implement the Corrective Action.]



Identification of Affected Parts (how to):



[State whether the affected components require visual inspection.]



Yes, as indicated below (and when DDS-4 or DAT72 is present)



[Explain how the field would identify the "bad" or affected

parts from the "good" or fixed parts.]



The door with the issue has features for an eject button and LED holes, the new

door does not have these features.



[Give precise commands, syntax, and sample output.]



N/A - There are no commands. This is a physical replacement only.



[State which Explorer files/directories might also be utilized

for determining affected parts/product.]



N/A



Hardware Remediation and Material Availability Details:

(For Hardware FABs only)



[List estimated dates seedstock material will be available

in each Timezone. This information should be acquired from

the Services Logistics representative.]



Material is currently available.



Comments:



[List anything specific to this asset that isn't already

listed above.]



References:



* BugID:

* Escalation ID:

* Sun Alert:

* Pending Patches:

* Resolution Patches:

* Other References:

* Reference Manual:

* Related URL(s):

* ECO: WO_29351

* GSAP:

* WW Stop Ship:

* Radiance ID:



Contacts:



* Contributor: Roy Stiles

* Responsible Engineer: [email protected]

* Responsible Manager: [email protected]

* Business Unit Group: SSG ES



[ ] SSG WGS (Workgroup Systems)

[ ] SSG NSN (Netra Systems and Networking)

[X] SSG ES (Enterprise Systems)

[ ] SSG SW (Platform Software)

[ ] SSG PNP (Processor)

[ ] NSG (Network Systems Group)

[ ] NWS (Network Storage)

[ ] OP/N1 RPE (Operating Platforms/N1 Revenue Product Engin.)

[ ] JPSE (Java Platform Sustaining Engineering)

[ ] JWSSE (Java Web Services Sustaining Engineering)

[ ] USG (User Software Group)

[ ] Other - Please specify
Product_uuid
63ff680d-0598-11d8-84cb-080020a9ed93|Sun Fire E2900 Server
6a74b2f9-bbd8-4b2c-870d-b6b73d6e224f|Sun Fire V1280 Server
e41a7084-3dbf-472d-918b-efb50dcbc220|Netra 1280 Server

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback