Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000038.1 : The Netra T2000 DIMM Locator Label mounted on the DIMM cover is incorrect.
PreviouslyPublishedAs 200050 Bug Id <SUNBUG: 6599898> Date of Preliminary Release 24-Sep-2007 Date of Resolved Release 06-Feb-2008 A customer or Field Engineer will replace the wrong DIMM if the DIMM Locator Label is used on a Netra T2000 system shipped prior to January 24, 2008 (see full details below). Impact A customer or Field Engineer will replace the wrong DIMM if the DIMM Locator Label is used on a Netra T2000 system shipped prior to January 24, 2008. This will only be seen when debugging a DIMM issue using Sun's POST in conjunction with the DIMM Locator Label. Contributing Factors The incorrect label is documented in the Identification of Affected Parts section of this asset. Sun Fire T2000 Servers are NOT impacted by this issue and currently have the proper DIMM Locator Label. Symptoms No initial symptoms. However, replacing the wrong DIMM will lead to additional troubleshooting time. Root Cause The DIMM Locator Label on the Netra T2000 was marked improperly during initial release. This label issue was corrected in systems manufactured after January 24, 2008 and as of Serial Number 0802FMP00R via ECO# WO_37812. Workaround Review the Netra T2000 Server Service Manual (819-5841-10 or later) Chapter 4.4 (Replacing a DIMM) prior to replacement of DIMMs on existing systems. Systems manufactured after ECO WO_37812 cut-in (which occured on January 24, 2008) will have a corrected DIMM Locator Label. Identification of Affected Parts (how to): Erroneous DIMM locators will differ from the Service Manual, as follows: 819-5841-10 Erroneous DIMM Service Manual Cover's Label C0/R1/D1(J0901) C0/R0/D0 C0/R0/D1(J0701) C0/R1/D0 C0/R1/D0(J0801) C0/R0/D1 C0/R0/D0(J0601) C0/R1/D1 -------- -------- C1/R1/D1(J1401) C1/R0/D0 C1/R0/D1(J1201) C1/R1/D0 C1/R1/D0(J1301) C1/R0/D1 C1/R0/D0(J1101) C1/R1/D1 CPU CPU C3/R0/D0(J2101) C2/R0/D0 C3/R1/D0(J2301) C2/R1/D0 C3/R0/D1(J2201) C2/R0/D1 C3/R1/D1(J2401) C2/R1/D1 -------- -------- C2/R0/D0(J1601) C3/R0/D0 C2/R1/D0(J1801) C3/R1/D0 C2/R0/D1(J1701) C3/R0/D1 C2/R1/D1(J1901) C3/R1/D1 Notice that the Rank and DIMM numbers are incorrect for channels 0 and 1. Also notice that channels 2 and 3 are reversed. Resolution Netra T2000 systems manufactured after January 24, 2008 and having a serial number of 0802FMP00R or later will not have this issue. For Netra T2000s shipped prior to this should use the workaround above. Modification History 06-Feb-2008: Updated from Preliminary to Resolved. Product Sun Netra T2000 Server Previously Published As 103075 Internal Comments Related Information (see full details below) Related Information
For information about FAB documents, its release processes, For Sun Authorized Service Providers go to: In addition to the above you may email: Internal Contributor/submitter [email protected] Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Eng Business Unit Group SSG ES (Enterprise Systems) Internal Kasp FAB Legacy ID 103075 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2007-09-24, 2008-01-24 Avoidance: Service Procedure Responsible Manager: [email protected] WF - Changed Status from Preliminary to Resolved, updated Issue Description and Resolution sections with final resolution information. - Joe 2/1/08 WF - RE still waiting for 1st Article of lablel. So FAB still listed as Preliminary. -Joe 11/12/07 WF - no feedback from Ext Rvw, sending to Publish. - Joe 9/24/07 WF - added second sentence under Impact section. FAB still under Ext Rvw. - Joe 9/21/07 Original Admin Info: WF - recvd final submission, drafted FAB and sent to Ext Rvw. - Joe 9/20/07 Product_uuid 7ba6ed6a-ec35-11da-ac3d-080020a9ed93|Netra T2000 Server Attachments This solution has no attachment |
||||||||||||
|