Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000020.1 : RAID 1 hard drive replacement incompatibility issue on Sun V20z/V40z.
PreviouslyPublishedAs 200023 Product Sun Fire V20z Server Sun Fire V40z Server Bug Id <SUNBUG: 6225636> <SUNBUG: 6333382> Part
Impact THIS POLICY IS FOR RAID 1 CRU ONLY. If a RAID 1 system has Fujitsu drives for both the primary and secondary drives and receives a Seagate drive as a FRU, then the mirror cannot be recreated because the Seagate drive is slightly smaller than the Fujitsu. The issue is that both, SEA and FUJ disks have the same X Option (X9256A) that is used when ordering these peripherals. The V20z and V40z OEM uses "generic industry" FW for their hard drives that create different volume capacities which will impact rebuilding RAID 1 array. The following paragraph summarize the policy: Replace a RAID 1 hard drive when:
Root Cause Disk mirroring can not be recreated when the replacement drive is smaller than the drive that was replaced. Mirroring function seizes. Smaller capacity drives do not have the data capacity of the larger hard drive. Workaround All RAID 1 mirroring broken 73GB hard drives should be replaced with PN: F371-0292-xx CRUs. Resolution The correction was made as follows:
Modification History Date: 12-JUL-2006
Previously Published As 102207 Internal Comments None Related Information
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-9464506 Internal Kasp FAB Legacy ID 102207 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: Avoidance: Workaround Responsible Manager: null Original Admin Info: null Product_uuid 1acc55b3-4b82-11d8-99fc-080020a9ed93|Sun Fire V20z Server 4726b78d-56d2-11d8-9e3a-080020a9ed93|Sun Fire V40z Server Attachments This solution has no attachment |
||||||||||||
|