Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek[tm] V2X2-V2X4f Shared Virtual Array Disk System: Hardware Specifications

  V2X2 V2X4f
Management
Storage Management Virtual Power Suite including SVA Administrator and SnapVantage software Virtual Power Suite including SVA Administrator and SnapVantage software
Data replication and copy SnapShot, PowerPPRC and PPRC SnapShot copy and remote mirroring software SnapShot, PowerPPRC and PPRC SnapShot copy and remote mirroring software
Backup and migration High Speed Data Mover and Transparent Data Migration Facility software High Speed Data Mover and Transparent Data Migration Facility software
Performance and Availability N/A PAV (static and dynamic)
Connectivity
Ports 4-32 ESCON ports, increments of 2 or 4 4-16 FICON ports, increments of 2 or 4
Logical Ports ESCON: 8,192 (512 per logical control unit) FICON: 2,048 (128 per logical control unit, 256 per FICON port)
Capacity
Usable Capacity Up to 11.6 TB Up to 23.2 TB
Device images supported 4096 - 3380 J/E/K
and/or 3390 1/2/3/Flexvolumes
or 1635 - 3390-9
4096 - 3380 J/E/K
and/or 3390 1/2/3/Flexvolumes
or 2730 - 3390-9
or 834 - 3390-27
Effective user cache capacity Up to 96 GB Up to 96 GB
Drive capacity 73 GB, 15,000 RPM Fiber Channel 146 GB, 15,000 RPM Fiber Channel
Environment
AC Voltage Range 200-240 VAC @ 50-60 Hz 200-240 VAC @ 50-60 Hz
Power consumption/dissipation 8.6 minimum kBTU/hr
12.4 maximum kBTU/hr
8.6 minimum kBTU/hr
12.4 maximum kBTU/hr
kVA 2.6 minimum/3.8 maximum 2.6 minimum/3.8 maximum
Temperature (operating) +60 to +90 F (+16 to +32 C) +60 to +90 F (+16 to +32 C)
Maximum wet bulb temperature +73 F (+23 C) +73 F (+23 C)
Relative Humidity (operating) 20% to 80% 20% to 80%
Mechanical
Height 61.0 in. (155.0 cm) 61.0 in. (155.0 cm)
Width 36.0 in. (92.0 cm) 36.0 in. (92.0 cm)
Depth 30.0 in. (77.0 cm) 30.0 in. (77.0 cm)
Weight 982.0 lb (445.0 kg) 982.0 lb (445.0 kg)
Service Clearance Front and Rear: 21.3 in (54.1 cm)
Side: 2.5 in (6.4 cm)
Front and Rear: 21.3 in (54.1 cm)
Side: 2.5 in (6.4 cm)
Regulations
Safety UL 1950; CAN/CSA 22.2 No. 950; EN60950
Emission FCC (47 CFR 15, Subpart B) Class A; CE (EN55022 Class A, EN55024, EN61000-3-2, EN61000-3-3)
VCCI (CISPR 22) Class A; Canada (ICES-003) Class A

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback