Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Ultra[tm] 30 Workstation: Hardware Specifications

Number One
Architecture 250- or 300-MHz UltraSPARC-II
Memory management MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported contexts
Cache memory

16-KB data and 16-KB instruction on chip

1 or 2-MB external

Capacities

16 DIMM module slots

Install SIMMs in sets of four. 16-, 32-, 64-, and 128-MB DIMM expansion

2 GB total memory capacity

Memory type 60-ns memory modules
Audio Four audio ports: headphone(out), line-in, line-out and microphone(in) using EIA standard 0.125-inch (3.5-mm) jacks
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45) or one MII for external transceiver connection
Keyboard and mouse One standard keyboard/mouse port (mini DIN-8)
Parallel One Centronics-compatible parallel port (DB25); ECP mode capable
PCI Four full-size PCI slots compliant with PCI specification version 2.1:
  • Three slots operating at 33-MHz, 32- or 64-bit data bus width, 5 volt;
  • One slot operating at 33- or 66-MHz, 32- or 64-bit data bus width, 3.3 volt
SCSI One 40-MB/sec, 68-pin, UltraSCSI (SCSI-3) (synchronous)
Serial Two RS-232C/RS-423 serial ports (DB25)
UPA graphics slot Two UPA graphics slots supporting up to two Creator3D or Elite3D m3, or one Elite3D m6 and one Creator3D or Elite3D m3 or Expert3D
Disks Up to two 3.5-x 1-in or x 1.6-in. disks; 2.1-GB, 4.2-GB, or 9.1-GB
Floppy Optional 3.5-in. MS-DOS/IBM compatible (720 KB, 1.2 MB, 1.44 MB formatted)
CD-ROM

SunCD 4x, 12x, or 32x 644-MB SCSI CD-ROM

Tape

Optional

  • 20- to 40-GB 4mm DDS-4
  • 12- to 24-GB 4mm DDS-3
  • 7- to 14-GB 8mm
  • 4- to 8-GB 4mm DDS-2
  • 4- to 8-GB 1/4" SLR
AC power 100 - 240 VAC, 47 - 63 Hz, 4 A(max), 0.4 KVA
Input power 300 W
Heat output 590 BTU/hr
Temperature Operating: 10° C to 40° C (50° F to 104° F) without tape drive; 10° C to 35° C (50° F to 95° F) with tape drive
Nonoperating: -20° C to 60° C ( -4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft)
Nonoperating: 12,000 m (40,000 ft)
Acoustic noise Operating: 6.1 bels
Idling: 5.9 bels
Vibration Operating: 0.2G, 5 to 500 to 5 Hz (5 sweeps), 3 perpendicular axes
Nonoperating: 1.0G, 5 to 500 to 5 Hz (5 sweeps), 3 perpendicular axes
Shock Operating: 5.0G, 11 milliseconds, half sine pulse
Nonoperating: 30G peak, 11 milliseconds, half sine pulse
Number of cords 1
Safety UL1950, CSA C22.2 No. 950, TUV EN 60950, CB Scheme with Nordic deviations EMKO-TSE (74-SEC) 203, ZH1/618
RFI/EMI FCC Class B, DOC Class B, VCCI Class 2, EN 55022 Class B, EN 61000-3-2
Immunity EN 50082-1
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree
Power management Energy Star compliant
Height 45.0 cm (17.7 in.)
Width 19.0 cm (7.5 in.)
Depth 49.8 cm (19.6 in.)
Weight 17.6 kg (38.8 lb.)

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.