Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Ultra[tm] 10 Workstation: Hardware Specifications

Architecture 300, 333, 360, or 440-MHz UltraSPARC[tm]-IIi
Cache Memory

16-KB instruction cache, 16-KB data cache

512-KB external cache for 300-MHz processor; 2 MB external cache for other processors

Capacities

Four DIMM slots

Install DIMMs in pairs (16 MB, 32 MB, 64 MB, 128 MB, and 256 MB DIMMs); quad provides best performance

1 GB maximum

Memory type 50ns or 60ns 168-pin JEDEC DIMMs, ECC error-correction
Audio Four audio ports: headphone(out), line-in, line-out and microphone(in) using EIA standard 0.125-inch (3.5-mm) jacks
Ethernet One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45), self-sensing
Graphics One graphics port (HD15), onboard 24-bit frame buffer
Keyboard and mouse One standard keyboard/mouse port (mini DIN-8)
Parallel One IEEE 1284 (bidirectional) parallel port (DB25)
PCI Four 32-bit PCI slots, full-size, 33 MHz, 5 volt
Serial One synchronous/asynchronous serial port (DB25); one asynchronous serial port (DB9)
UPA graphics slot One 100-MHz UPA graphics slot; supports Creator, Creator3D,and Elite3D high-performance graphics options
Disks Up to two 4.3 GB (4500 rpm) or 9.1/20.4 GB (7200 rpm), 3.5-in. Enhanced IDE HDD
Floppy One 3.5-in. 1.44-MB floppy
CD-ROM 24X-, 32X, or 48X-speed CD-ROM
Tape No tape supported
AC input 90 - 132 VAC or 180 - 264 VAC (switch selectable), 47 - 63 Hz, 4 A (max), 0.4 KVA
Input power 380 W
Heat output 1287 BTU/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60° C (�4° F to 140° F)
Humidity Operating: 40% to 80% relative humidity, noncondensing
Nonoperating: 30% to 90% relative humidity, noncondensing
Altitude Operating: 3000 m (10,000 ft)
Nonoperating: 12,000 m (40,000 ft)
Acoustic noise Operating: 5.2 bels
Idling: 5.2 bels
Number of cords 1
Safety UL 1950, CSA C22.2 No.950, TUV EN 60950, CB Scheme with Nordic deviations, EMKO-TSE (74-SEC)203, ZH1/618
RFI/EMI FCC Class B, DOC Class B, VCCI Class 2, EN 55022 Class B, EN 61000-3-2
Immunity EN 50082-1
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree
Power management Energy Star compliant
Height 40.2 cm (15.8 in.)
Width 17.6 cm (6.9 in.)
Depth 43.5 cm (17.1 in.)
Weight 20.0 kg (44 lb.)

 


  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback