Component |
Tips |
CPU |
-
A limited number of AMD Opteron "Rev F" CPUs in certain systems can cause instability
in some specific configurations. (FAB
1019389.1)
|
Ethernet |
-
Small number of Northstar Dual GBE -03 cards may fail on certain systems due to defective voltage mux.
(FAB 1000525.1).
|
Firmware |
-
Failure to update Sun Fire X4600 M2 to Software release 2.1 exposes system to any issue corrected by this release.
(FAB 1019435.1).
|
Memory |
-
Specific Micron 4GB DIMMs are experiencing Multiple/Single Bit Error failures on some platforms with AMD Quad Core (Barcelona) processors.(FAB 1019713.1).
|
|