Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4100 Server: Hardware Specifications

Processor
Number 1 or 2 (Single or Dual-Core)
Architecture Type: AMD Opteron Processor 200 Series
Single Core: 248 (2.2GHz), 252 (2.6GHz), or 254 (2.8GHz)
Dual Core: 275 (2.2GHz), 280 (2.4GHz), or 285 (2.6GHz)
Cache memory 1 MB Level 2 cache per processor core
Main Memory
Capacities DIMM slots per processor: 4
DIMM slots per System Board: 8 (using 2 processors)
DIMM type: DDR1/400 ECC registered DIMMs (128 bit plus ECC databus)
DIMM size: 512-MB, 1-GB, or 2-GB
Maximum capacity: 16GB (when configured with 2-GB DIMMs and 2 processors)
Standard Integrated Interfaces
Network Four 10/100/1000Base-T Ethernet ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS Four channel SAS interface, internal access only.
ATI Rage XL Video Chip, VGA Video 15-pin Port
USB Front: One USB 1.1 port
Rear: Two USB 1.1 ports
Expansion bus Two internal MD2 low profile PCI-X slots
  • one at 64-bit/100MHz (slot 0)
  • one at 64-bit/133MHz (slot 1)
Internal Mass Storage
Disks Up to four hot-swap Disks (36GB, 73GB or 146GB 10K RPM SAS HDD) without DVD-ROM
DVD-ROM One EIDE ATAPI Slot Loading DVD-ROM (optional)
Power Supplies
Dual redundant, hot swappable power supplies
(Maximum DC output = 550W)
(Maximum AC input = 550W x 1.33 efficiency = 733W)
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3000 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 500 m above 500 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise Single, non-rack system:
Less than 83 dB sound power in ambient temperature of up to 24° C
Vibration Single, non-rack system:
.20 G, 5 to 500 Hz sine sweep
Shock Single, non-rack system:
5 G, 11 ms half-sine
Regulations
Meets or exceeds the following requirements:
Safety IEC60950, UL/CSA60950, EN60950, CB Scheme with all country differences
RFI/EMI FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003
Immunity EN55024, EN300-386:v1.31
Certifications Safety: cULus Mark, TUV GS Mark, CE Mark, CCC, GOST R, S-Mark
EMC: CE Mark (93/68/EEC), Emissions and Immunity Class A Emissions Levels: FCC, VCCI, BSMI, C-tick, MIC, CCC, GOST
Dimensions and Weight
Height 43.8 mm (1.72 in.)
Width 455 mm (17.5 in.)
Depth 640 mm (25.2 in.)
Weight 18.6 kg (41.1 lb.) maximum with rack kit
8.0 kg (17.0 lb.) maximum without rack kit
Rack Mounting
Optional Slide Rail Kit (X8029A)2is a 4-point mounted slide rail kit.
Sun Fire X4100 and X4200 Server Racks (using the X8029A kit) Racks are as follows:
  • Sun Rack 900
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Third Party EIA-310-D3
2 The slide kit includes hardware that enables mounting to any of the following types of rack rails:
  • 6 mm threaded holes
  • #10-32 threaded holes
  • #10 threaded holes
3 These must be compliant racks which have mounting depths of 27-30 inches.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.