Racking |
Fits into a standard 19 inch wide rack. Four post rack kit adjustable
between 720 mm and 925 mm
|
Processor |
Number |
One or two |
Architecture |
1GHz, 1.28GHz, 1.33GHz, or 1.5GHz UltraSPARC® IIIi, 64 bit,
4-way Superscalar SPARC® V9
|
Cache memory |
64 KB data, 32 KB instruction and 1 MB integrated L2 |
Main Memory |
Capacities |
4 DIMM slots per processor, registered
DDR-1 SDRAM
(PC2100/PC2700) 128 bit + ECC databus
System configurations from 512 MB to 16 GB
|
Standard Interfaces |
Ethernet |
Four 10/100/1000 BaseT Ethernet
One 10 BaseT Ethernet (Network Management)
|
PCI |
Three internal PCI 2.2 compliant expansion slots:
One 64 bit 33/66 MHz 3.3V full-length
Two 64 bit 33 MHz 5V full-length
Note:Nominal power = maximum 25W per slot, maximum 45W across 3 slots
|
SCSI |
One Ultra160 SCSI multimode (SE/LVD) |
Serial |
One TIA/EIA-232-F asynchronous (DB9) Port
One TIA/EIA-232-F (RJ45) Port (Serial Management)
|
System Configuration Reader and Card |
Front accessible for transfer of system configuration information,
including host ID |
USB |
Two OHCI-1.0 Compliant Interfaces, supporting dual speeds of
12 and 1.5 Mbits/sec each |
Internal Mass Storage |
Disks |
Up to four hot-swap Ultra160 SCSI 36GB, 73GB, or 146GB Disks |
DVD-ROM |
One Slim-line ATAPI DVD-ROM (Optional) |
Environment |
AC input |
90 - 264 VAC (47 - 63 Hz) |
Input power |
546 W |
Nominal power (calculated at 240V/50Hz) |
Minimum configuration: 215 Watts
(1 × 1.34GHz processor, 2 × 256MB DIMMs,
1 × 73GB HDD)
Maximum configuration: 442 Watts
(2 × 1.5GHz processors, 8 × 1GB DIMMs,
2 × 73GB HDDs, Crypto 500, 1 × DVD-ROM,
3 × PCI cards [max power spec 45W for three cards])
Typical Minimum configuration: 200 Watts
(1 × 1.34GHz processor, 2 × 256MB DIMMs,
1 × 73GB HDD)
Typical Maximum configuration: 329 Watts
(2 × 1.5GHz processors, 8 × 1GB DIMMs,
2 × 73GB HDDs, Crypto 500, 1 × DVD-ROM,
3 × PCI cards [max power spec 45W for three cards])
|
Heat dissipation |
Minimum configuration: 798 BTU/hr
Maximum configuration: 1639 BTU/hr |
Temperature |
Operating:
5° C to 40° C (41° F to 104° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F)
|
Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27° C max wet bulb
Nonoperating:
Up to 93% relative humidity, noncondensing, 38° C max wet bulb |
Altitude |
Operating:
Up to 3000 m, maximum ambient temperature is derated by 1° C
per 500 m above 500 m
Nonoperating:
Up to 12000 m |
Acoustic noise |
Operating: Less than 7.3 B sound power in ambient temperature
of up to 24° C |
Regulations
Meets or exceeds the following requirements:
|
Safety |
IEC60950, UL/CSA60950, EN60950 |
Emissions |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22 |
Immunity |
EN55024 |
Certification |
Safety:
cULus Mark, TUV GS Mark, CE Mark
EMC:
CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, CTICK
|
Dimensions and Weights |
Height |
87.66 mm (3.4 in.) (2 RU) |
Width |
425 mm (16.73 in.) |
Depth |
635 mm (25 in.) |
Weight |
19 kg (41.8 lb.) fully configured; 22.4 kg (49.31 lb.) with rack-mount
rails and cable management arm |