Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V210 Server: Hardware Specifications

Racking
Fits into a standard 19 inch wide rack. Four post rack kit adjustable between 720 mm and 925 mm
Processor
Number One or two
Architecture 1GHz, 1.33GHz UltraSPARC® IIIi, 64 bit, 4-way Superscalar SPARC® V9
Cache memory 64 KB data, 32 KB instruction and 1 MB integrated L2
Main Memory
Capacities 4 DIMM slots per processor, registered DDR-1 SDRAM
(PC2100/PC2700) 128 bit + ECC databus
System configurations from 512 MB to 16 GB
Standard Interfaces
Ethernet Four 10/100/1000 BaseT Ethernet
One 10 BaseT Ethernet (Network Management)
PCI One 64 bit 33/66 MHz 3.3V full-length slot (PCI 2.2 compliant)
Note:Nominal power = maximum 25W
SCSI One Ultra-320 SCSI multimode (SE/LVD)
Serial One TIA/EIA-232-F asynchronous (DB9) Port
One TIA/EIA-232-F (RJ45) Port (Serial Management)
System Configuration Reader and Card Front accessible for transfer of system configuration information, including host ID
USB Two OHCI-1.0 Compliant Interfaces, supporting dual speeds of 12 and 1.5 Mbits/sec each
Internal Mass Storage
Disks Up to two hot-swap Ultra-320 SCSI 36GB, 73GB, or 146GB Disks
DVD-ROM One Slim-line ATAPI DVD-ROM (Optional)
Environment
AC input 90 - 264 VAC (47 - 63 Hz)
Input power 459 W
Nominal power
(calculated at 240V/50Hz)
Minimum configuration: 206 Watts
  (1 × 1.34GHz processor, 2 × 256MB DIMMs, 1 × 73GB HDD)
Maximum configuration: 411 Watts
  (2 × 1.34GHz processors, 8 × 1GB DIMMs, 2 × 73GB HDDs, Crypto 500,
  1 × DVD-ROM, 1 × PCI card [max power spec 25W])
Typical Minimum configuration: 179 Watts
  (1 × 1.34GHz processor, 2 × 256MB DIMMs, 1 × 73GB HDD)
Typical Maximum configuration: 296 Watts
  (2 × 1.34GHz processors, 8 × 1GB DIMMs, 2 × 73GB HDDs, Crypto 500,
  1 × DVD-ROM, 1 × PCI card [max power spec 25W])
Heat dissipation Minimum configuration: 704 BTU/hr
Maximum configuration: 1406 BTU/hr
Temperature Operating: 5° C to 40° C (41° F to 104° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity Operating: 10% to 90% relative humidity noncondensing, 27°C max wet bulb
Nonoperating: Up to 93% relative humidity, noncondensing, 38°C max wet bulb
Altitude Operating: Up to 3000 m, maximum ambient temperature is derated by 2° C per 500 m above 500 m
Nonoperating: Up to 12000 m
Acoustic noise Operating: Less than 7.3 B sound power in ambient temperature of up to 24° C
Regulations
Meets or exceeds the following requirements:
Safety IEC60950, UL/CSA60950, EN60950
Emissions FCC Class A, Part 15 47 CFR, EN55022, CISPR 22
Immunity EN55024
Certification Safety: cULus Mark, TUV GS Mark, CE Mark
EMC: CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, CTICK
Dimensions and Weights
Height 43.2 mm (1.7 in.) (1 RU)
Width 425 mm (16.73 in.)
Depth 635 mm (25 in.)
Weight 12 kg (26.4 lb.) fully configured; 15.6 kg (34.31 lb.) with rack-mount rails and cable management arm

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.